Evidence map›Paper›PMID 32153375›Full record

ArticleFrontiers in human neuroscience2020

Predicting

M Arcan Erturk, Eric Panken, Mark J Conroy, Jonathan Edmonson, Jeff Kramer, Jacob Chatterton, S Riki Banerjee

Abstract read
In one paragraph

Article in Frontiers in human neuroscience, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

M Arcan ErturkRestorative Therapies Group, Implantables R&D, Medtronic PLC, Minneapolis, MN, United States.
Eric PankenRestorative Therapies Group, Implantables R&D, Medtronic PLC, Minneapolis, MN, United States.
Mark J ConroyRestorative Therapies Group, Implantables R&D, Medtronic PLC, Minneapolis, MN, United States.
Jonathan EdmonsonCardiac Rhythm Heart Failure, Device Product Engineering, Medtronic PLC, Minneapolis, MN, United States.
Jeff KramerRestorative Therapies Group, Implantables R&D, Medtronic PLC, Minneapolis, MN, United States.
Jacob ChattertonRestorative Therapies Group, Implantables R&D, Medtronic PLC, Minneapolis, MN, United States.
S Riki BanerjeeRestorative Therapies Group, Implantables R&D, Medtronic PLC, Minneapolis, MN, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionMRI gradient-fields may induce extrinsic voltage between electrodes and conductive neurostimulator enclosure of implanted deep brain stimulation (DBS) systems, and may cause unintended stimulation and/or malfunction. Electromagnetic (EM) simulations using detailed anatomical human models, therapy implant trajectories, and gradient coil models can be used to calculate clinically relevant induced voltage levels. Incorporating additional anatomical human models into the EM simulation library can help to achieve more clinically relevant and accurate induced voltage levels, however, adding new anatomical human models and developing implant trajectories is time-consuming, expensive and not always feasible.

methodsMRI gradient-field induced voltage levels are simulated in six adult human anatomical models, along clinically relevant DBS implant trajectories to generate the dataset. Predictive artificial neural network (ANN) regression models are trained on the simulated dataset. Leave-one-out cross validation is performed to assess the performance of ANN regressors and quantify model prediction errors.

resultsMore than 180,000 unique gradient-induced voltage levels are simulated. ANN algorithm with two fully connected layers is selected due to its superior generalizability compared to support vector machine and tree-based algorithms in this particular application. The ANN regression model is capable of producing thousands of gradient-induced voltage predictions in less than a second with mean-squared-error less than 200 mV.

conclusionWe have integrated machine learning (ML) with computational modeling and simulations and developed an accurate predictive model to determine MRI gradient-field induced voltage levels on implanted DBS systems.

Indexed as

DBS implant trajectoriesDBS MR conditional testinggradient-induced voltageintegrating machine learning and computational modelingMRI gradient-field modeling

Identifiers

PMID32153375
PMCPMC7044348

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.