ArticleJournal of synchrotron radiation2020
ID15A at the ESRF - a beamline for high speed operando X-ray diffraction, diffraction tomography and total scattering.
Article in Journal of synchrotron radiation, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 38 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
38 citing papers in PubMed.
- Deterministic segmentation of grains in dense Laue microdiffraction datasets.Journal of applied crystallography · 2026Article
- Enhancing Room-Temperature Hydrogen Storage Properties in Ti-V-Cr-Nb-Mo/Fe Multielement Alloys via Substitutional Tuning.ACS omega · 2026Article
- Identifying and Mitigating Adverse X‑ray Induced Effects in Operando Spectroscopic Studies of Copper Exchanged Zeolites.The journal of physical chemistry. C, Nanomaterials and interfaces · 2025Article
- Pt nanoparticles breathe and reversibly detach from AlNature communications · 2025Article
- A low-background setup for in situ X-ray total scattering combined with fast scanning calorimetry.Journal of synchrotron radiation · 2025Article
- An X-ray beamline for utilizing intense, high-energy undulator radiation.Journal of synchrotron radiation · 2025Article
- The High Energy diffraction beamline at the Canadian Light Source.Journal of synchrotron radiation · 2025Article
- Enhancing high-energy powder X-ray diffraction applications using a PILATUS4 CdTe detector.Journal of synchrotron radiation · 2025Article
- Phase Stability of High Entropy (Mg,Ni,Co,Cu,Zn)O from Temperature-Resolved Synchrotron Diffraction: Tetragonal Distortion and Guggenite Phase.Small (Weinheim an der Bergstrasse, Germany) · 2025Article
- Characterization and calibration of DECTRIS PILATUS3 X CdTe 2M high-Journal of applied crystallography · 2025Article
- Article
- A miniature X-ray diffraction setup on ID20 at the European Synchrotron Radiation Facility.Journal of synchrotron radiation · 2024Article
- Quantitative localisation of titanium in the framework of titanium silicalite-1 using anomalous X-ray powder diffraction.Nature communications · 2024Article
- Hard X-ray operation of X-ray gas monitors at the European XFEL.Journal of synchrotron radiation · 2024Article
- ForMAX - a beamline for multiscale and multimodal structural characterization of hierarchical materials.Journal of synchrotron radiation · 2024Article
- xrdPlanner: exploring area detector geometries for powder diffraction and total scattering experiments.Journal of synchrotron radiation · 2024Article
- Sub-micrometre focusing of intense 100 keV X-rays with multilayer reflective optics.Journal of synchrotron radiation · 2024Article
- Exploring high-throughput synchrotron X-Ray powder diffraction for the structural analysis of pharmaceuticals.International journal of pharmaceutics: X · 2023Article
- Recent developments in X-ray diffraction/scattering computed tomography for materials science.Philosophical transactions. Series A, Mathematical, physical, and engineering sciences · 2023Review
- Local Order in Liquid Gallium-Indium Alloys.The journal of physical chemistry. C, Nanomaterials and interfaces · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
19 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
ID15A is a newly refurbished beamline at the ESRF devoted to operando and time-resolved diffraction and imaging, total scattering and diffraction computed tomography. The beamline is optimized for rapid alternation between the different techniques during a single operando experiment in order to collect complementary data on working systems. The high available energy (up to 120 keV) means that even bulky and highly absorbing systems may be studied. The beamline is equipped with optimized focusing optics and a photon-counting CdTe pixel detector, allowing for both unprecedented data quality at high energy and for very rapid triggered experiments. A large choice of imaging detectors and ancillary probes and sample environments is also available.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.