ReviewJournal of thoracic disease2020
Driving blind: instituting SEP-1 without high quality outcomes data.
Review in Journal of thoracic disease, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 14 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 1 synthesis or guideline pooled it, 36 citations in OpenAlex.
- The Effect of Severe Sepsis and Septic Shock Management Bundle (SEP-1) Compliance and Implementation on Mortality Among Patients With Sepsis : A Systematic Review.Annals of internal medicine · 2025Pooled it
- Artificial Intelligence to Facilitate SEP-1 Measure Compliance and Fluid Management in Sepsis.Journal of clinical medicine · 2026Review
- Complex Sepsis Presentations, SEP-1 Compliance, and Outcomes.JAMA network open · 2025Article
- SepsisJournal of medical microbiology · 2025Review
- Overcultured? Blood cultures on discharged ED patients were ordered more frequently after the SEP-1 bundle initiation.The American journal of emergency medicine · 2023Article
- Outcomes Associated With Rural Emergency Department Provider-to-Provider Telehealth for Sepsis Care: A Multicenter Cohort Study.Annals of emergency medicine · 2023Article
- Compliance with SEP-1 guidelines is associated with improved outcomes for septic shock but not for severe sepsis.Journal of intensive medicine · 2022Article
- Association Between Implementation of the Severe Sepsis and Septic Shock Early Management Bundle Performance Measure and Outcomes in Patients With Suspected Sepsis in US Hospitals.JAMA network open · 2021Observational
- Four consecutive yearly point-prevalence studies in Wales indicate lack of improvement in sepsis care on the wards.Scientific reports · 2021Article
- Erratum to driving blind: instituting SEP-1 without high quality outcomes data.Journal of thoracic disease · 2021Article
- Modify Centers for Medicare & Medicaid Services' Sepsis Core Measure (SEP-1) Now to Optimize Care for COVID-19.Annals of internal medicine · 2021Article
- RegardingJournal of thoracic disease · 2021Article
- Individualized Care Is Superior to Standardized Care for the Majority of Critically Ill Patients.Critical care medicine · 2020Article
- The management of sepsis: science & fiction.Journal of thoracic disease · 2020Article
Corrections and comments
- Commented on byRegarding2021
- Erratum issued
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In 2015, the Centers for Medicare and Medicaid Services (CMS) instituted an all-or-none sepsis performance measure bundle (SEP-1) to promote high-quality, cost-effective care. Systematic reviews demonstrated only low-quality evidence supporting most of SEP-1's interventions. CMS has removed some but not all of these unproven components. The current SEP-1 version requires patients with suspected sepsis have a lactate level, blood cultures, broad-spectrum antibiotics and, if hypotensive, a fixed 30 mL/kg fluid infusion within 3 hours, and a repeat lactate if initially elevated within 6 hours. Experts have continued to raise concerns that SEP-1 remains overly prescriptive, lacks a sound scientific basis and presents risks (overuse of antibiotics and inappropriate fluids not titrated to need). To incentivize compliance with SEP-1, CMS now publicly publishes how often hospitals complete all interventions in individual patients. However, compliance measured across hospitals (5 studies, 48-2,851 hospitals) or patients (three studies, 110-851 patients) has been low (approximately 50%) which is not surprising given SEP-1's lack of scientific basis. The largest observational study (1,738 patients) reporting survival rates employing SEP-1 found they were not significantly improved with the measure (P=0.53) as did the next largest study (851 patients, adjusted survival odds ratio 1.36, 95% CI, 0.85 to 2.18). Two smaller observational studies (158 and 450 patients) reported SEP-1 improved unadjusted survival (P≤0.05) but were confounded either by baseline imbalances or by simultaneous introduction of a code sepsis protocol to improve compliance. Regardless, retrospective studies have well known biases related to non-randomized designs, uncontrolled data collection and failure to adjust for unrecognized influential variables. Such low-quality science should not be the basis for a national mandate compelling care for a rapidly lethal disease with a high mortality rate. Instead, SEP-1 should be based on high quality reproducible evidence from randomized controlled trials (RCT) demonstrating its benefit and thereby safety. Otherwise we risk not only doing harm but standardizing it.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials