Evidence map›Paper›PMID 32147892›Full record

ArticleJournal of magnetic resonance imaging : JMRI2020

Quantitative MRCP Imaging: Accuracy, Repeatability, Reproducibility, and Cohort-Derived Normative Ranges.

Marc H Goldfinger, Gerard R Ridgway, Carlos Ferreira, Caitlin R Langford, Lin Cheng, Arina Kazimianec, Andrea Borghetto, Thomas G Wright, Gary Woodward, Neelam Hassanali and 11 more

2 registry-linked trialsAbstract read
In one paragraph

Article in Journal of magnetic resonance imaging : JMRI, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 35 papers.

0numbers the graph read from it
0cells of the map it votes in
35citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05359497 naunknown statusnot on this mapstarted 2022, after this paper: background citation

Value of MRCP+ And Liver Multiscan in the Management of Dominant Strictures in Primary Sclerosing Cholangitis

TypeinterventionalSponsorAcademisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)Ran2022 to 2023Enrolled50ConditionsPSC, MRIArmsLiver Multiscan sequences baseline, MRCP+ analysis baseline, Liver Multiscan analysis baseline, MRI liver with MRCP, Liver Multiscan sequences follow-up
NCT05462093 nanot yet recruitingnot on this mapstarted 2022, after this paper: background citation

Clinical Application of Annual Liver Multiscan and MRCP+ in Primary Sclerosing Cholangitis: the CATCH-IT Study

TypeinterventionalSponsorAcademisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)Ran2022 to 2029Enrolled200ConditionsPrimary Sclerosing CholangitisArmsLiver Multiscan sequences, Liver Multiscan analysis, MRCP+
3 · Its place in the literature

Who cites it

35 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Observational
  5. Practical applications of AI in body imaging.Abdominal radiology (New York) · 2026
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Unmet needs in autoimmune liver diseases.Current opinion in immunology · 2025
    Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

21 authors.

Marc H GoldfingerPerspectum Ltd, Oxford, UK.ORCID 0000-0002-2289-7117
Gerard R RidgwayPerspectum Ltd, Oxford, UK.
Carlos FerreiraPerspectum Ltd, Oxford, UK.
Caitlin R LangfordPerspectum Ltd, Oxford, UK.
Lin ChengPerspectum Ltd, Oxford, UK.
Arina KazimianecPerspectum Ltd, Oxford, UK.
Andrea BorghettoPerspectum Ltd, Oxford, UK.
Thomas G WrightPerspectum Ltd, Oxford, UK.
Gary WoodwardPerspectum Ltd, Oxford, UK.
Neelam HassanaliPerspectum Ltd, Oxford, UK.
Rowan C NichollsPerspectum Ltd, Oxford, UK.
Hayley SimpsonPerspectum Ltd, Oxford, UK.
Tom WaddellPerspectum Ltd, Oxford, UK.
Siddarth VikalPerspectum Ltd, Oxford, UK.
Marija MavarPerspectum Ltd, Oxford, UK.
Soubera RymellPerspectum Ltd, Oxford, UK.
Ioan WigleyPerspectum Ltd, Oxford, UK.
Jaco JacobsPerspectum Ltd, Oxford, UK.
Matt KellyPerspectum Ltd, Oxford, UK.
Rajarshi BanerjeePerspectum Ltd, Oxford, UK.
J Michael BradyPerspectum Ltd, Oxford, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMagnetic resonance cholangiopancreatography (MRCP) is an important tool for noninvasive imaging of biliary disease, however, its assessment is currently subjective, resulting in the need for objective biomarkers. PURPOSE: To investigate the accuracy, scan/rescan repeatability, and cross-scanner reproducibility of a novel quantitative MRCP tool on phantoms and in vivo. Additionally, to report normative ranges derived from the healthy cohort for duct measurements and tree-level summary metrics. STUDY TYPE: Prospective. PHANTOMS/SUBJECTS: Phantoms: two bespoke designs, one with varying tube-width, curvature, and orientation, and one exhibiting a complex structure based on a real biliary tree. Subjects Twenty healthy volunteers, 10 patients with biliary disease, and 10 with nonbiliary liver disease. SEQUENCE/FIELD STRENGTH: MRCP data were acquired using heavily T ASSESSMENT: Digital instances of the phantoms were synthesized with varying resolution and signal-to-noise ratio. Physical 3D-printed phantoms were scanned across six scanners (two field strengths for each of three manufacturers). Human subjects were imaged on four scanners (two fieldstrengths for each of two manufacturers). STATISTICAL TESTS: Bland-Altman analysis and repeatability coefficient (RC).

resultsAccuracy of the diameter measurement approximated the scanning resolution, with 95% limits of agreement (LoA) from -1.1 to 1.0 mm. Excellent phantom repeatability was observed, with LoA from -0.4 to 0.4 mm. Good reproducibility was observed across the six scanners for both phantoms, with a range of LoA from -1.1 to 0.5 mm. Inter- and intraobserver agreement was high. Quantitative MRCP detected strictures and dilatations in the phantom with 76.6% and 85.9% sensitivity and 100% specificity in both. Patients and healthy volunteers exhibited significant differences in metrics including common bile duct (CBD) maximum diameter (7.6 mm vs. 5.2 mm P = 0.002), and overall biliary tree volume 12.36 mL vs. 4.61 mL, P = 0.0026). DATA

conclusionThe results indicate that quantitative MRCP provides accurate, repeatable, and reproducible measurements capable of objectively assessing cholangiopathic change. Evidence Level: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;52:807-820.

Indexed as

Cholangiopancreatography, Magnetic ResonanceImage Processing, Computer-AssistedHumansMagnetic Resonance ImagingPhantoms, ImagingProspective StudiesReproducibility of Results3D-printed phantombiliary diseasemagnetic resonance cholangiopancreatography (MRCP)quantitative metricsrepeatabilityreproducibility

Identifiers

PMID32147892
PMCPMC7496952

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials