Evidence map›Paper›PMID 32147807›Full record

SynthesisThe Cochrane database of systematic reviews2020

Ab interno trabecular bypass surgery with Schlemm´s canal microstent (Hydrus) for open angle glaucoma.

Francisco Otarola, Gianni Virgili, Anupa Shah, Kuang Hu, Catey Bunce, Gus Gazzard

Open access · bronzeAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers, 8 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
29citing papers in PubMed, 8 pooled it
4.8field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

29 citing papers in PubMed, 8 syntheses or guidelines pooled it, 46 citations in OpenAlex.

  1. Minimally invasive trabecular meshwork surgery for open-angle glaucoma.The Cochrane database of systematic reviews · 2026
    Pooled it
  2. Ab interno supraciliary microstent surgery for open-angle glaucoma.The Cochrane database of systematic reviews · 2021
    Pooled it
  3. Pooled it
  4. Acupuncture for glaucoma.The Cochrane database of systematic reviews · 2020
    Pooled it
  5. Ab interno trabecular bypass surgery with iStent for open-angle glaucoma.The Cochrane database of systematic reviews · 2019
    Pooled it
  6. Pooled it
  7. Pooled it
  8. Pooled it
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Review
  17. Review
  18. Endophthalmitis Associated With XEN Stent Implantation.American journal of ophthalmology · 2023
    Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 4 countries.

Francisco Otarola *Moorfields Eye Hospital NHS Foundation Trust, Glaucoma Service, 162 City Road, London, UK, EC1V 2PD.
Gianni Virgili *University of Florence, Department of Neurosciences, Psychology, Drug Research and Child Health (NEUROFARBA), Largo Palagi, 1, Florence, Italy, 50134.
Anupa ShahLondon School of Hygiene & Tropical Medicine, Cochrane Eyes and Vision, ICEH, Keppel Street, London, UK, WC1E 7HT.
Kuang HuMoorfields Eye Hospital NHS Foundation Trust, Glaucoma Service, 162 City Road, London, UK, EC1V 2PD.
Catey BunceKing's College London, School of Population Health & Environmental Sciences, Faculty of Life Sciences & Medicine, 4th Floor, Addison House, Guy's Campus, London, UK, SE1 1UL.
Gus GazzardMoorfields Eye Hospital NHS Foundation Trust, Glaucoma Service, 162 City Road, London, UK, EC1V 2PD.
Moorfields Eye Hospital NHS Foundation Trust · GBKing's College London · GBLondon School of Hygiene & Tropical Medicine · GBUniversity of Florence · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundGlaucoma is a leading cause of irreversible blindness. A number of minimally-invasive surgical techniques have been introduced as a treatment to prevent glaucoma from progressing; ab interno trabecular bypass surgery with the Schlemm's canal Hydrus microstent is one of them.

objectivesTo evaluate the efficacy and safety of ab interno trabecular bypass surgery with the Hydrus microstent in treating people with open angle glaucoma (OAG). SEARCH

methodsOn 7 May 2019, we searched CENTRAL (2019, Issue 5), which contains the Cochrane Eyes and Vision Trials Register; Ovid MEDLINE; Ovid Embase; the ISRCTN registry; ClinicalTrials.gov; and the WHO ICTRP. SELECTION CRITERIA: We searched for randomised controlled trials (RCTs) of the Hydrus microstent, alone or with cataract surgery, compared to other surgical treatments (cataract surgery alone, other minimally-invasive glaucoma device techniques, trabeculectomy), laser treatment, or medical treatment. DATA COLLECTION AND ANALYSIS: A minimum of three authors independently extracted data from reports of included studies, using a data collection form and analysed data, based on standard Cochrane methods. MAIN

resultsWe included three published studies, with 808 people randomised. Two studies had multiple international recruitment centres in the USA and other countries. The third study had several sites based in Europe. All three studies were sponsored by the Hydrus manufacturer Ivantis Inc. All studies included participants with mainly mild or moderate OAG (mean deviation between -3.6 dB (decibel) and -8.4 dB in all study arms), which was controlled with medication in many participants (mean medicated intraocular pressure (IOP) 17.9 mmHg to 19.1 mmHg). There were no concerns regarding allocation concealment bias, but masking of outcome assessors was high or unclear risk in all studies; masking of participants was achieved, and losses to follow-up were not a concern. Two studies compared the Hydrus microstent combined with cataract surgery to cataract surgery alone, in participants with visually significant cataracts and OAG. We found moderate-certainty evidence that adding the Hydrus microstent to cataract surgery increased the proportion of participants who were medication-free from about half to more than three quarters at 12-month, short-term follow-up (risk ratio (RR) 1.59, 95% confidence interval (CI) 1.39 to 1.83; 2 studies, 639 participants; I² = 0%; and 24-month, medium-term follow-up (RR 1.63, 95% CI 1.40 to 1.88; 2 studies, 619 participants; I² = 0%). The Hydrus microstent combined with cataract surgery reduced the medium-term mean change in unmedicated IOP (after washout) by 2 mmHg more compared to cataract surgery alone (mean difference (MD) -2.00, 95% CI -2.69 to -1.31; 2 studies, 619 participants; I² = 0%; moderate-certainty evidence), and the mean change in IOP-lowering drops (MD -0.41, 95% CI -0.56 to -0.27; 2 studies, 619 participants; I² = 0%; low-certainty evidence). We also found low-certainty evidence that adding a Hydrus microstent to cataract surgery reduced the need for secondary glaucoma surgery from about 2.5% to less than 1% (RR 0.17, 95% CI 0.03 to 0.86; 2 studies, 653 participants; I² = 27%; low-certainty evidence). Intraocular bleeding, loss of 2 or more visual acuity (VA) lines, and IOP spikes of 10 mmHg or more were rare in both groups; estimates were imprecise, and included both beneficial and harmful effects. There were no cases of endophthalmitis in either group. No data were available on the proportion of participants achieving IOP less than 21 mmHg, 17 mmHg, or 14 mmHg; health-related quality of life (HRQOL), or visual field progression. One study provided short-term data for the Hydrus microstent compared with the iStent trabecular micro-bypass stent (iStent: implantation of two devices in a single procedure) in 152 participants with OAG (148 in analyses). Use of the Hydrus increased the proportion of medication-free participants from about a quarter to about half compared to those who received iStent, but this estimate was imprecise (RR 1.94, 95% CI 1.21 to 3.11; low-certainty evidence). Use of the Hydrus microstent reduced unmedicated IOP (after washout) by about 3 mmHg more than the iStent (MD -3.10, 95% CI -4.17 to -2.03; moderate-certainty evidence), and the use of IOP-lowering medication (MD -0.60, 95% CI -0.99 to -0.21; low-certainty evidence). Both devices achieved a final IOP < 21 mmHg in most participants (Hydrus microstent: 91.8%; iStent: 84%; RR 1.09, 95% CI 0.97 to 1.23; low-certainty evidence). None of the participants who received the Hydrus microstent (N = 74) required additional glaucoma surgery; two participants who received the iStent (N = 76) did. Few adverse events were found in either group. No data were available on the proportion of participants achieving IOP less than 17 mmHg or 14 mmHg, or on HRQOL. AUTHORS'

conclusionsIn people with cataracts and generally mild to moderate OAG, there is moderate-certainty evidence that the Hydrus microstent with cataract surgery compared to cataract surgery alone, likely increases the proportion of participants who do not require IOP lowering medication, and may further reduce IOP at short- and medium-term follow-up. There is moderate-certainty evidence that the Hydrus microstent is probably more effective than the iStent in lowering IOP of people with OAG in the short-term. Few studies were available on the effects of the Hydrus microstent, therefore the results of this review may not be applicable to all people with OAG, particularly in selected people with medically uncontrolled glaucoma, since IOP was controlled with medication in many participants in the included studies. Complications may be rare using the Hydrus microstent, as well as the comparator iStent, but larger studies are needed to investigate its safety.

Indexed as

Glaucoma Drainage ImplantsCataract ExtractionGlaucoma, Open-AngleHumansRandomized Controlled Trials as TopicTrabeculectomy

Identifiers

PMID32147807
PMCPMC7061024
OpenAlexW2742229680

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.