ArticleArchives of orthopaedic and trauma surgery2020
Conventional instruments are more accurate for measuring the depth of the tibial cut than computer-assisted surgery in total knee arthroplasty: a prospective study.
Article in Archives of orthopaedic and trauma surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 17 citations in OpenAlex.
- Correlation between frontal knee alignment and bone resection thicknesses during total knee arthroplasty without precision-enabling device: a retrospective study.Archives of orthopaedic and trauma surgery · 2025Article
- Femoral resection accuracy and precision in manual caliper-verified kinematic alignment total knee arthroplasty.Journal of experimental orthopaedics · 2025Article
- Long leg radiographs underestimate the degree of constitutional varus limb alignment and joint line obliquity in comparison with computed tomography: a radiographic study.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Article
- Arithmetic hip-knee-ankle angle and stressed hip-knee-ankle angle: equivalent methods for estimating constitutional lower limb alignment in kinematically aligned total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022Article
- A Surgeon That Switched to Unrestricted Kinematic Alignment with Manual Instruments Has a Short Learning Curve and Comparable Resection Accuracy and Outcomes to Those of an Experienced Surgeon.Journal of personalized medicine · 2022Article
- An insert with less than spherical medial conformity causes a loss of passive internal rotation after calipered kinematically aligned TKA.Archives of orthopaedic and trauma surgery · 2021Article
- A ligament tensor-guided extramedullary alignment technique for distal femoral cut in total knee replacement: results at a minimum 3 years follow-up.Archives of orthopaedic and trauma surgery · 2021Article
- Assistive technologies in knee arthroplasty: fashion or evolution? Rate of publications and national registries prove the Scott Parabola wrong.Archives of orthopaedic and trauma surgery · 2021Review
- Handheld computer-navigated constrained total knee arthroplasty for complex extra-articular deformities.Archives of orthopaedic and trauma surgery · 2021Article
- Pros and cons of navigated versus conventional total knee arthroplasty-a retrospective analysis of over 2400 patients.Archives of orthopaedic and trauma surgery · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThe most commonly used tool for implant positioning are conventional instruments (CI) followed by computer-assisted surgery (CAS). A number of studies have investigated the cutting error of the tibial component when CAS is used, but most of them were focused on the cutting angles. The accuracy of CAS to determine the depth of the cut has not received much attention, even though implications are similar or worse, than with an angle mismatch. MATERIALS AND
methodsThis was an ethics board approved, prospective study of 23 consecutive varus TKAs by a single surgeon. Implant positioning was performed using CAS; however, the depth of the tibial cut was determined with both CAS and CI. Targeted alignment was the mechanical axis and 3° of posterior slope. The planned and the achieved cut, as determined by CAS needed to match. The achieved cut was then measured using a caliper and compared to the depth of the cut as per CAS. Medial and lateral cuts were analyzed separately. Analysis of variance and Bland-Altman plots were used for the comparison.
resultsMean medial navigated cut was 6.3 (± 2.2) mm, mean measured medial cut was 6.6 (± 2.3) mm. Mean lateral navigated cut was 8.9 (± 1.8) mm, mean measured lateral cut was 8.8 (± 1.5) mm. There was a statistical significance for both the medial (p < 0.001) and the lateral (p = 0.004) navigated and measured cuts.
conclusionsThe results of this study suggest that the tibial cut depth, measured by the navigation, does not match the actual bony cuts performed, even if a perfect cut was achieved in both sagittal and coronal plane. Surgeons should be aware of the measurement error in the navigation system and potentially add an additional step for verifying the achieved depth of the cut.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.