Evidence map›Paper›PMID 32146591›Full record

ArticleArchives of orthopaedic and trauma surgery2020

Conventional instruments are more accurate for measuring the depth of the tibial cut than computer-assisted surgery in total knee arthroplasty: a prospective study.

Antonio Klasan, Sven Edward Putnis, Samuel Grasso, Thomas Neri, Myles Raphael Coolican

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.9field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Antonio KlasanSydney Orthopaedic Research Institute, 445 Victoria Ave, Chatswood, 2067, Australia. klasan.antonio@me.com.
Sven Edward PutnisSydney Orthopaedic Research Institute, 445 Victoria Ave, Chatswood, 2067, Australia.
Samuel GrassoSydney Orthopaedic Research Institute, 445 Victoria Ave, Chatswood, 2067, Australia.
Thomas NeriSydney Orthopaedic Research Institute, 445 Victoria Ave, Chatswood, 2067, Australia.
Myles Raphael CoolicanSydney Orthopaedic Research Institute, 445 Victoria Ave, Chatswood, 2067, Australia.
Sydney Orthopaedic Research Institute · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe most commonly used tool for implant positioning are conventional instruments (CI) followed by computer-assisted surgery (CAS). A number of studies have investigated the cutting error of the tibial component when CAS is used, but most of them were focused on the cutting angles. The accuracy of CAS to determine the depth of the cut has not received much attention, even though implications are similar or worse, than with an angle mismatch. MATERIALS AND

methodsThis was an ethics board approved, prospective study of 23 consecutive varus TKAs by a single surgeon. Implant positioning was performed using CAS; however, the depth of the tibial cut was determined with both CAS and CI. Targeted alignment was the mechanical axis and 3° of posterior slope. The planned and the achieved cut, as determined by CAS needed to match. The achieved cut was then measured using a caliper and compared to the depth of the cut as per CAS. Medial and lateral cuts were analyzed separately. Analysis of variance and Bland-Altman plots were used for the comparison.

resultsMean medial navigated cut was 6.3 (± 2.2) mm, mean measured medial cut was 6.6 (± 2.3) mm. Mean lateral navigated cut was 8.9 (± 1.8) mm, mean measured lateral cut was 8.8 (± 1.5) mm. There was a statistical significance for both the medial (p < 0.001) and the lateral (p = 0.004) navigated and measured cuts.

conclusionsThe results of this study suggest that the tibial cut depth, measured by the navigation, does not match the actual bony cuts performed, even if a perfect cut was achieved in both sagittal and coronal plane. Surgeons should be aware of the measurement error in the navigation system and potentially add an additional step for verifying the achieved depth of the cut.

Indexed as

Arthroplasty, Replacement, KneeSurgery, Computer-AssistedHumansProspective StudiesTibiaArthroplastyBone cutKneeNavigationTibial component

Identifiers

PMID32146591
OpenAlexW3009948658

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.