Evidence map›Paper›PMID 32143605›Full record

ArticleBMC musculoskeletal disorders2020

Complex biomechanical properties of non-augmented and augmented pedicle screws in human vertebrae with reduced bone density.

Martin Schulze, Oliver Riesenbeck, Thomas Vordemvenne, Michael J Raschke, Julia Evers, René Hartensuer, Dominic Gehweiler

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. [Cement augmentation in spinal surgery].Unfallchirurgie (Heidelberg, Germany) · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Martin SchulzeUniversity Hospital Münster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, 48149, Münster, Germany. schulze.martin@uni-muenster.de.ORCID http://orcid.org/0000-0003-2899-1558
Oliver RiesenbeckUniversity Hospital Münster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, 48149, Münster, Germany.
Thomas VordemvenneUniversity Hospital Münster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, 48149, Münster, Germany.
Michael J RaschkeUniversity Hospital Münster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, 48149, Münster, Germany.
Julia EversUniversity Hospital Münster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, 48149, Münster, Germany.
René HartensuerUniversity Hospital Münster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, 48149, Münster, Germany.
Dominic GehweilerUniversity Hospital Münster, Department of Trauma, Hand and Reconstructive Surgery, Albert-Schweitzer-Campus 1, 48149, Münster, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn osteoporotic bone, the quality of the bone-to-implant interface is decreased, which may lead to early implant failure. Screw anchorage can be improved by augmentation. This effect is mainly investigated with a pull-out test. To our knowledge, the effect of cement augmentation in an in vivo physiological setup focusing on screw movement has not been investigated to date. The aim of this work was to investigate and compare augmented and native screw behavior in a physiologically related setup.

methodsTwelve fresh-frozen human lumbar vertebrae were divided into two groups. Each vertebra was bilaterally instrumented with either non-augmented or augmented pedicle screw systems and loaded in a recently developed test setup that provided cyclic conditions comparable to a physiological gait. The cyclic loading should test the primary implant stability, comparable to the postoperative period of two months in a worst-case scenario in the absence of osseous remodeling. Screws were tracked optically, and screw movement and failure patterns were observed.

resultsMutual influence between the left and right sides resulted in a successive, rather than simultaneous, failure. Augmentation of the screws in vertebrae with poor bone quality reduced screw subsidence and thus improved the rigidity of the screw-to-implant interface by up to six-fold. The non-augmented condition was significantly related to early screw failure.

conclusionsPedicle screw system failure involves a complex bilateral-coupled mechanism. The cyclic loading based on physiological conditions during walking has allowed the postoperative conditions and clinical failure mechanisms to be simulated in vitro and clarified. Future implant systems should be investigated with a physiologically related setup.

Indexed as

Bone DensityPedicle ScrewsAgedAged, 80 and overBiomechanical PhenomenaBone-Anchored ProsthesisBone CementsBone-Implant InterfaceHumansLumbar VertebraeMaterials TestingMiddle AgedOsteoporosisPolymethyl MethacrylateProsthesis FailureSpinal FusionBone CementsPolymethyl MethacrylateBiomechanicsCyclic loadingLumbar vertebraePedicle screwsPhysiologically related setupReduced BMD

Identifiers

PMID32143605
PMCPMC7060638

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.