Evidence map›Paper›PMID 32142428›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2020

Incoherent Clutter Suppression Using Lag-One Coherence.

Will Long, Nick Bottenus, Gregg E Trahey

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Large-Array Deep Abdominal Imaging in Fundamental and Harmonic Mode.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2023
    Article
  3. Article
  4. Adaptive Models for Multi-Covariate Imaging of Sub-Resolution Targets (MIST).IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2022
    Article
  5. Spatial Coherence in Medical Ultrasound: A Review.Ultrasound in medicine & biology · 2022
    Review
  6. Spatiotemporal Coherence to Quantify Sources of Image Degradation in Ultrasonic Imaging.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2022
    Article
  7. Article
  8. Reverberation Clutter Suppression Using 2-D Spatial Coherence Analysis.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2022
    Article
  9. Frequency-Dependent Spatial Coherence in Conventional and Chirp Transmissions.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2021
    Article
  10. Histogram Matching for Visual Ultrasound Image Comparison.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2021
    Article
  11. Coherence-based quantification of acoustic clutter sources in medical ultrasound.The Journal of the Acoustical Society of America · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Will Long
Nick Bottenus
Gregg E Trahey

Funding

Coherence-Based Fetal Ultrasonic ImagingR01EB017711 · NIBIB · DUKE UNIVERSITY · PI TRAHEY, GREGG E. · 2014 to 2025
$4.7M
Large aperture and wideband modular ultrasound arrays for the diagnosis of liver cancerR01CA211602 · NCI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI FERRARA, KATHERINE W, TRAHEY, GREGG E. · 2017 to 2021
$3.3M
A Patient-Adaptive, High MI Abdominal ScannerR01EB026574 · NIBIB · DUKE UNIVERSITY · PI TRAHEY, GREGG E. · 2018 to 2021
$2.3M
NCI NIH HHS R01 CA211602NIBIB NIH HHS R01 EB017711NIBIB NIH HHS R01 EB026574
6 · The paper itself

Abstract

The lag-one coherence (LOC), derived from the correlation between the nearest-neighbor channel signals, provides a reliable measure of clutter which, under certain assumptions, can be directly related to the signal-to-noise ratio of individual channel signals. This offers a direct means to decompose the beamsum output power into contributions from speckle and spatially incoherent noise originating from acoustic clutter and thermal noise. In this study, we applied a novel method called lag-one spatial coherence adaptive normalization (LoSCAN) to locally estimate and compensate for the contribution of spatially incoherent clutter from conventional delay-and-sum (DAS) images. Suppression of incoherent clutter by LoSCAN resulted in improved image quality without introducing many of the artifacts common to other adaptive imaging methods. In simulations with known targets and added channel noise, LoSCAN was shown to restore native contrast and increase DAS dynamic range by as much as 10-15 dB. These improvements were accompanied by DAS-like speckle texture along with reduced focal dependence and artifact compared with other adaptive methods. Under in vivo liver and fetal imaging conditions, LoSCAN resulted in increased generalized contrast-to-noise ratio (gCNR) in nearly all matched image pairs ( N = 366 ) with average increases of 0.01, 0.03, and 0.05 in good-, fair-, and poor-quality DAS images, respectively, and overall changes in gCNR from -0.01 to 0.20, contrast-to-noise ratio (CNR) from -0.05 to 0.34, contrast from -9.5 to -0.1 dB, and texture μ/σ from -0.37 to -0.001 relative to DAS.

Indexed as

AlgorithmsArtifactsFemaleFetusHumansImage Processing, Computer-AssistedLiverPhantoms, ImagingPregnancySignal Processing, Computer-AssistedUltrasonographyUltrasonography, Prenatal

Identifiers

PMID32142428
PMCPMC8033959

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.