Percutaneous Atrial Septal Defect Closure Using the Occlutech Figulla Device in Adults: More than 800 Patient-Years of Follow-Up.

R J R Snijder, L E Renes, D Bosshardt, M J Suttorp, J M Ten Berg, M C Post

Open access · goldAbstract read
In one paragraph

Article in Journal of interventional cardiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.1field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Echocardiographic right ventricular remodeling after percutaneous atrial septal defect closure.International journal of cardiology. Congenital heart disease · 2023
    Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

R J R SnijderDepartment of Cardiology, St. Antonius Hospital, Nieuwegein, Netherlands.ORCID https://orcid.org/0000-0003-2246-0617
L E RenesDepartment of Emergency Medicine, St. Antonius Hospital, Nieuwegein, Netherlands.
D BosshardtDepartment of Cardiology, St. Antonius Hospital, Nieuwegein, Netherlands.
M J SuttorpDepartment of Cardiology, St. Antonius Hospital, Nieuwegein, Netherlands.
J M Ten BergDepartment of Cardiology, St. Antonius Hospital, Nieuwegein, Netherlands.
M C PostDepartment of Cardiology, St. Antonius Hospital, Nieuwegein, Netherlands.ORCID https://orcid.org/0000-0001-7400-5996
St. Antonius Ziekenhuis · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe Occlutech Figulla occluder has been proven safe and effective at midterm follow-up after percutaneous atrial septal defect (ASD) closure. We describe the safety and efficacy at long-term follow-up in adults.

methodsAll consecutive adult patients that underwent ASD closure between 2008 and 2015 were included. All complications were registered. Residual left-to-right shunt (LRS) was diagnosed using color-Doppler transthoracic echocardiography (TTE). Right-to-left shunting was diagnosed using contrast TTE. Successful closure was defined as no LRS at follow-up.

resultsIn total, 166 patients (mean age 56.7 ± 16.1 years; 62% female) underwent percutaneous ASD closure using the Occlutech Flex I (70%) or Flex II (30%) device (diameter 24 mm; range 10-40 mm) under general anaesthesia and transoesophageal echocardiographic guidance. Long-term follow-up data were available for 144 patients (87%) with a mean follow-up of 5.9 ± 2.6 years, a total of 814 patient-years. During hospitalization, device embolization occurred in three patients (1.8%) with successful extraction in all. During the long-term follow-up, 15 patients (9.8%) suffered new-onset atrial fibrillation and stroke occurred in 2.1%. There was no residual LRS at 12-month follow-up. No device embolization occurred during the long-term follow-up.

conclusionPercutaneous ASD closure using the Occlutech device appears to be safe at long-term follow-up with a high successful closure rate at one year.

Indexed as

Postoperative ComplicationsSeptal Occluder DeviceCardiac CatheterizationEchocardiography, Doppler, ColorFemaleFollow-Up StudiesHeart Septal Defects, AtrialHumansMaleMiddle AgedNetherlandsOutcome and Process Assessment, Health CareProsthesis Design