Evidence map›Paper›PMID 32133570›Full record

ArticleWorld journal of urology2020

Role of intraoperative ultrasound in robotic-assisted radical nephrectomy with inferior vena cava thrombectomy in renal cell carcinoma.

Qiuyang Li, Nan Li, Yukun Luo, Hongkai Yu, Xin Ma, Xu Zhang, Jie Tang

Abstract read
PubMed Publisher
In one paragraph

Article in World journal of urology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Qiuyang Li *Department of Ultrasound, Chinese PLA General Hospital, Beijing, 100853, China.
Nan Li *Department of Ultrasound, Chinese PLA General Hospital, Beijing, 100853, China.
Yukun LuoDepartment of Ultrasound, Chinese PLA General Hospital, Beijing, 100853, China. lyk301@163.com.
Hongkai YuDepartment of Urology, Chinese PLA General Hospital, Beijing, 100853, China.
Xin MaDepartment of Urology, Chinese PLA General Hospital, Beijing, 100853, China.
Xu ZhangDepartment of Urology, Chinese PLA General Hospital, Beijing, 100853, China.
Jie TangDepartment of Ultrasound, Chinese PLA General Hospital, Beijing, 100853, China. txiner@vip.sina.com.
Chinese PLA General Hospital · CN

Funding

the National Nature Science Foundation of China 81801698
6 · The paper itself

Abstract

purposeTo determine the impact of intraoperative ultrasound on robotic-assisted radical nephrectomy with inferior vena cava (IVC) tumor thrombectomy in renal cell carcinoma (RCC).

methodsWe retrospectively analyzed intraoperative records of 27 patients with RCC and invasion of the IVC who underwent robotic-assisted nephrectomy with tumor thrombectomy at our center between December 2017 and July 2018. Diagnostic utility and impact of intraoperative transesophageal echocardiography (TEE), intraoperative robotic-assisted ultrasonography, and intraoperative contrast-enhanced ultrasound (CEUS) on surgical management were extracted from the surgical notes and intraoperative ultrasound reports.

resultsTwenty-seven patients with thrombus had intraoperative ultrasound. Complete tumor removal was achieved in 22 patients, IVC transection in 5 patients, and no residual tumor was observed in all patients. Intraoperative TEE changed the robotic surgical strategy in three patients by monitoring thrombus-level regression. Downstaging of the thrombus level occurred in three patients: Levels IV to III in one and Levels III to II in two. Intraoperative robotic-assisted ultrasonography has facilitated safe VC clamp placement and identification and protection of collateral vessels during IVC transection in five patients. Intraoperative CEUS helped to differentiate the boundary between tumor thrombus (enhancement and small vessel pulsation) and bland thrombus (hypoechoic or no enhancement) in eight (29.6%) patients with bland thrombus.

conclusionsIntraoperative ultrasound is a safe, minimally invasive technique that can provide accurate real-time information regarding the presence and extent of IVC involvement and guidance for placement of a vena cava clamp, confirming the character of the thrombus to plan an optimal surgical approach.

Indexed as

Neoplastic Cells, CirculatingRobotic Surgical ProceduresSurgery, Computer-AssistedUltrasonography, InterventionalVena Cava, InferiorAgedCarcinoma, Renal CellFemaleHumansKidney NeoplasmsMaleMiddle AgedNephrectomyRetrospective StudiesThrombectomyTreatment OutcomeInferior vena cavaRenal cell carcinomaRoboticsThrombectomyUltrasound

Identifiers

PMID32133570
OpenAlexW3009982958

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.