Evidence map›Paper›PMID 32133387›Full record

ArticleOrthopaedic journal of sports medicine2020

Biomechanical Evaluation of a Novel Loop Retention Mechanism for Cortical Graft Fixation in ACL Reconstruction.

Tobias Götschi, George Rosenberg, Xiang Li, Chen Zhang, Elias Bachmann, Jess G Snedeker, Sandro F Fucentese

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Suspension button constructs restore posterior knee laxity in solid tibial avulsion of the posterior cruciate ligament.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2021
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Tobias GötschiInstitute for Biomechanics, ETH Zurich, Zurich, Switzerland.
George RosenbergInstitute for Biomechanics, ETH Zurich, Zurich, Switzerland.
Xiang LiInstitute for Biomechanics, ETH Zurich, Zurich, Switzerland.
Chen ZhangInstitute for Biomechanics, ETH Zurich, Zurich, Switzerland.
Elias BachmannInstitute for Biomechanics, ETH Zurich, Zurich, Switzerland.
Jess G SnedekerInstitute for Biomechanics, ETH Zurich, Zurich, Switzerland.
Sandro F FucenteseDepartment of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
ETH Zurich · CHInstitute for Biomedical Engineering · CHSecond Affiliated Hospital of Xi'an Jiaotong University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundImplant fixation by means of a cortical fixation device (CFD) has become a routine procedure in anterior cruciate ligament reconstruction. There is no clear consensus whether adjustable-length CFDs are more susceptible to loop lengthening when compared with pretied fixed-length CFDs. PURPOSE: To assess biomechanical performance measures of 3 types of CFDs when subjected to various loading protocols. STUDY

designControlled laboratory study.

methodsThree types of CFDs underwent biomechanical testing: 1 fixed length and 2 adjustable length. One of the adjustable-length devices is based on the so-called finger trap mechanism, and the other is based on a modified sling lock mechanism. A device-only test of 5000 cycles (n = 8 per group) and a tendon-device test of 1000 cycles (n = 8 per group) with lower and upper force limits of 50 and 250 N, respectively, were applied, followed by ramp-to-failure testing. Adjustable-length devices then underwent further cyclic testing with complete loop unloading (n = 5 per group) at each cycle, as well as fatigue testing (n = 3 per group) over a total of 1 million cycles. Derived mechanical parameters were compared among the devices for statistical significance using Kruskal-Wallis analysis of variance followed by post hoc Mann-Whitney

resultsAll CFDs showed elongation <2 mm after 5000 cycles when tested in an isolated manner and withstood ultimate tensile forces in excess of estimated peak in vivo forces. In both device-only and tendon-device tests, differences in cyclic performance were found among the devices, favoring adjustable-length fixation devices over the fixed-length device. Completely unloading the suspension loops, however, led to excessive loop lengthening of the finger trap device, whereas the modified sling lock device remained stable throughout the test. The fixed-length device displayed superior ultimate strength over both adjustable-length devices. Both adjustable-length devices showed adequate fatigue behavior during high-cyclic testing.

conclusionAll tested devices successfully prevented critical construct elongation when tested with constant tension and withstood ultimate loads in excess of estimated in vivo forces during the rehabilitation phase. The finger trap device gradually lengthened excessively when completely unloaded during cyclic testing. CLINICAL RELEVANCE: Critical loop lengthening may occur if adjustable-length devices based on the finger trap mechanism are repeatedly unloaded in situ.

Indexed as

ACL reconstructionadjustable buttonbiomechanical testingcortical fixationcyclic loading

Identifiers

PMID32133387
PMCPMC7042561
OpenAlexW3009026201

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.