ArticleBiomedical optics express2020
Quality improvement of adaptive optics retinal images using conditional adversarial networks.
Article in Biomedical optics express, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Forecasting the diabetic retinopathy progression using generative adversarial networks.Communications medicine · 2025Article
- Quantifying image quality in AOSLO images of photoreceptors.Biomedical optics express · 2024Article
- Semi-supervised generative adversarial learning for denoising adaptive optics retinal images.Biomedical optics express · 2024Article
- The optics of the human eye at 8.6 µm resolution.Scientific reports · 2021Article
- Emulated retinal image capture (ERICA) to test, train and validate processing of retinal images.Scientific reports · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The adaptive optics (AO) technique is widely used to compensate for ocular aberrations and improve imaging resolution. However, when affected by intraocular scatter, speckle noise, and other factors, the quality of the retinal image will be degraded. To effectively improve the image quality without increasing the imaging system's complexity, the post-processing method of image deblurring is adopted. In this study, we proposed a conditional adversarial network-based method for directly learning an end-to-end mapping between blurry and restored AO retinal images. The proposed model was validated on synthetically generated AO retinal images and real retinal images. The restoration results of synthetic images were evaluated with the metrics of peak signal-to-noise ratio (PSNR), structural similarity (SSIM), perceptual distance, and error rate of cone counting. Moreover, the blind image quality index (BIQI) was used as the no-reference image quality assessment (NR-IQA) algorithm to evaluate the restoration results on real AO retinal images. The experimental results indicate that the images restored by the proposed method have sharper quality and higher signal-to-noise ratio (SNR) when compared with other state-of-the-art methods, which has great practical significance for clinical research and analysis.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.