Evidence map›Paper›PMID 32130554›Full record

ArticleEJNMMI physics2020

Comparison of the Biograph Vision and Biograph mCT for quantitative

Britt Kunnen, Casper Beijst, Marnix G E H Lam, Max A Viergever, Hugo W A M de Jong

Open access · goldAbstract read
In one paragraph

Article in EJNMMI physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
3.0field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 31 citations in OpenAlex.

  1. Article
  2. Article
  3. Phantom-based evaluation of yttrium-90 datasets using biograph vision quadra.European journal of nuclear medicine and molecular imaging · 2023
    Article
  4. Lesion Quantification Accuracy of DigitalJournal of nuclear medicine : official publication, Society of Nuclear Medicine · 2023
    Article
  5. Safety and Efficacy of 90Y-FAPI-46 Radioligand Therapy in Patients with Advanced Sarcoma and Other Cancer Entities.Clinical cancer research : an official journal of the American Association for Cancer Research · 2022
    Article
  6. Lung Dose Measured on PostradioembolizationJournal of nuclear medicine : official publication, Society of Nuclear Medicine · 2022
    Article
  7. Initial Clinical Experience withJournal of nuclear medicine : official publication, Society of Nuclear Medicine · 2022
    Article
  8. Post Yttrium-90 Imaging.Seminars in interventional radiology · 2021
    Review
  9. High quality imaging and dosimetry for yttrium-90 (European journal of nuclear medicine and molecular imaging · 2021
    Article
  10. Article
  11. Initial Experience withDiagnostics (Basel, Switzerland) · 2021
    Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Britt KunnenDepartment of Radiology and Nuclear Medicine, UMC Utrecht, P.O. Box 85500, GA 3508, Utrecht, the Netherlands. B.Kunnen@umcutrecht.nl.ORCID http://orcid.org/0000-0003-0027-7280
Casper BeijstDepartment of Radiology and Nuclear Medicine, UMC Utrecht, P.O. Box 85500, GA 3508, Utrecht, the Netherlands.
Marnix G E H LamDepartment of Radiology and Nuclear Medicine, UMC Utrecht, P.O. Box 85500, GA 3508, Utrecht, the Netherlands.
Max A ViergeverImage Sciences Institute, UMC Utrecht & University Utrecht, Heidelberglaan 100, CX 3584, Utrecht, the Netherlands.
Hugo W A M de JongDepartment of Radiology and Nuclear Medicine, UMC Utrecht, P.O. Box 85500, GA 3508, Utrecht, the Netherlands.
Utrecht University · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundNew digital PET scanners with improved time of flight timing and extended axial field of view such as the Siemens Biograph Vision have come on the market and are expected to replace current generation photomultiplier tube (PMT)-based systems such as the Siemens Biograph mCT. These replacements warrant a direct comparison between the systems, so that a smooth transition in clinical practice and research is guaranteed, especially when quantitative values are used for dosimetry-based treatment guidance. The new generation digital PET scanners offer increased sensitivity. This could particularly benefit

methodsThe NEMA image quality phantom was scanned to determine the ideal reconstruction settings for the Vision. In addition, an anthropomorphic phantom was scanned with both the Vision and the mCT, mimicking a radioembolisation patient with lung, liver, tumour, and extrahepatic deposition inserts. Image quantification of the anthropomorphic phantom was assessed by the lung shunt fraction, the tumour to non-tumour ratio, the parenchymal dose, and the contrast to noise ratio of extrahepatic depositions.

resultsFor the Vision, a reconstruction with 3 iterations, 5 subsets, and no post-reconstruction filter is recommended for quantitative

conclusionsWe recommend to reconstruct

Indexed as

PET/CTRadioembolisationYttrium-90

Identifiers

PMID32130554
PMCPMC7056802
OpenAlexW3011559202

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.