Evidence map›Paper›PMID 32130149›Full record

ArticleJMIR medical informatics2020

Performance of Computer-Aided Diagnosis in Ultrasonography for Detection of Breast Lesions Less and More Than 2 cm: Prospective Comparative Study.

Liang Yongping, Ping Zhou, Zhang Juan, Zhao Yongfeng, Wengang Liu, Yifan Shi

Open access · goldAbstract read
In one paragraph

Article in JMIR medical informatics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.7field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Liang Yongping *The Third Xiangya Hospital, Central South University, Changsha, Hunan, China.ORCID https://orcid.org/0000-0003-1510-5991
Ping ZhouThe Third Xiangya Hospital, Central South University, Changsha, Hunan, China.ORCID https://orcid.org/0000-0003-1121-7339
Zhang Juan *The Third Xiangya Hospital, Central South University, Changsha, Hunan, China.ORCID https://orcid.org/0000-0001-5089-723X
Zhao YongfengThe Third Xiangya Hospital, Central South University, Changsha, Hunan, China.ORCID https://orcid.org/0000-0002-0777-1890
Wengang LiuThe Third Xiangya Hospital, Central South University, Changsha, Hunan, China.ORCID https://orcid.org/0000-0001-5907-0511
Yifan ShiThe Third Xiangya Hospital, Central South University, Changsha, Hunan, China.ORCID https://orcid.org/0000-0001-6551-2697
Central South University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundComputer-aided diagnosis (CAD) is used as an aid tool by radiologists on breast lesion diagnosis in ultrasonography. Previous studies demonstrated that CAD can improve the diagnosis performance of radiologists. However, the optimal use of CAD on breast lesions according to size (below or above 2 cm) has not been assessed.

objectiveThe aim of this study was to compare the performance of different radiologists using CAD to detect breast tumors less and more than 2 cm in size.

methodsWe prospectively enrolled 261 consecutive patients (mean age 43 years; age range 17-70 years), including 398 lesions (148 lesions>2 cm, 79 malignant and 69 benign; 250 lesions≤2 cm, 71 malignant and 179 benign) with breast mass as the prominent symptom. One novice radiologist with 1 year of ultrasonography experience and one experienced radiologist with 5 years of ultrasonography experience were each assigned to read the ultrasonography images without CAD, and then again at a second reading while applying the CAD S-Detect. We then compared the diagnostic performance of the readers in the two readings (without and combined with CAD) with breast imaging. The McNemar test for paired data was used for statistical analysis.

resultsFor the novice reader, the area under the receiver operating characteristic curve (AUC) improved from 0.74 (95% CI 0.67-0.82) from the without-CAD mode to 0.88 (95% CI 0.83-0.93; P<.001) at the combined-CAD mode in lesions≤2 cm. For the experienced reader, the AUC improved from 0.84 (95% CI 0.77-0.90) to 0.90 (95% CI 0.86-0.94; P=.002). In lesions>2 cm, the AUC moderately decreased from 0.81 to 0.80 (novice reader) and from 0.90 to 0.82 (experienced reader). The sensitivity of the novice and experienced reader in lesions≤2 cm improved from 61.97% and 73.23% at the without-CAD mode to 90.14% and 97.18% (both P<.001) at the combined-CAD mode, respectively.

conclusionsS-Detect is a feasible diagnostic tool that can improve the sensitivity for both novice and experienced readers, while also improving the negative predictive value and AUC for lesions≤2 cm, demonstrating important application value in the clinical diagnosis of breast cancer.

trial registrationChinese Clinical Trial Registry ChiCTR1800019649; http://www.chictr.org.cn/showprojen.aspx?proj=33094.

Indexed as

breast imaging reporting and data system (BI-RADS)breast neoplasmbreast neoplasms diagnosiscancer screeningcomputer diagnostic aidultrasonography

Identifiers

PMID32130149
PMCPMC7076404
OpenAlexW3003488448

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked