Artificial urinary sphincter: current status and future directions.

Culley C Carson

Open access · goldAbstract readReview
In one paragraph

Review in Asian journal of andrology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed, 1 pooled it
2.8field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 1 synthesis or guideline pooled it, 39 citations in OpenAlex.

  1. Pooled it
  2. Case - Artificial urinary sphincter pressure-regulating balloon perforation following increased intra-abdominal pressure.Canadian Urological Association journal = Journal de l'Association des urologues du Canada · 2026
    Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Article
  13. The Asia-Pacific AMS800 artificial urinary sphincter consensus statement.International journal of urology : official journal of the Japanese Urological Association · 2023
    Review
  14. Article
  15. Review
  16. Review
  17. Introduction to the 12Asian journal of andrology
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author at 1 institution in 1 country.

Culley C CarsonDepartment of Urology, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
University of North Carolina at Chapel Hill · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Urge urinary incontinence (UUI) is one of the most troublesome complications of surgery of the prostate whether for malignancy or benign conditions. For many decades, there have been attempts to reduce the morbidity of this outcome with variable results. Since its development in the 1970s, the artificial urinary sphincter (AUS) has been the "gold standard" for treatment of the most severe cases of UUI. Other attempts including injectable bulking agents, previous sphincter designs, and slings have been developed, but largely abandoned because of poor long-term efficacy and significant complications. The AUS has had several sentinel redesigns since its first introduction to reduce erosion and infection and increase efficacy. None of these changes in the basic AUS design have occurred in the past three decades, and the AUS remains the same despite newer technology and materials that could improve its function and safety. Recently, newer compressive devices and slings to reposition the bladder neck for men with mild-to-moderate UUI have been developed with success in select patients. Similarly, the AUS has had applied antibiotic coating to all portions except the pressure-regulating balloon (PRB) to reduce infection risk. The basic AUS design, however, has not changed. With newer electronic technology, the concept of the electronic AUS or eAUS has been proposed and several possible iterations of this eAUS have been reported. While the eAUS is as yet not available, its development continues and a prototype device may be available soon. Possible design options are discussed in this review.

Indexed as

Urinary Sphincter, ArtificialHumansProstatectomyProsthesis DesignUrinary Incontinence, Urgeartificial sphincterbladder slingprostatesphincterurinary incontinence

Identifiers

PMID32129191
PMCPMC7155799
OpenAlexW3008326584

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.