Evidence map›Paper›PMID 32126109›Full record

ArticlePloS one2020

Pre-/analytical factors affecting whole blood and plasma glucose concentrations in loggerhead sea turtles (Caretta caretta).

Patricia E Kunze, Justin R Perrault, Yu-Mei Chang, Charles A Manire, Samantha Clark, Nicole I Stacy

Abstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Blood analytes relevant to nutritional status and energy metabolism in three sea turtle species across nesting season.Journal of comparative physiology. B, Biochemical, systemic, and environmental physiology · 2026
    Article
  3. Article
  4. Ecometabolomics of Loggerhead Sea Turtles (International journal of molecular sciences · 2025
    Article
  5. Article
  6. Article
  7. Article
  8. Comparison of 2 glucose analytical methodologies in immature Kemp's ridley sea turtles: dry chemistry of plasma versus point-of-care glucometer analysis of whole blood.Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc · 2021
    Article
  9. Heat, health and hatchlings: associations ofConservation physiology · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Patricia E KunzeRoyal Veterinary College, University of London, London, United Kingdom.ORCID 0000-0002-1728-0614
Justin R PerraultLoggerhead Marinelife Center, Juno Beach, Florida, United States of America.ORCID 0000-0002-5046-6701
Yu-Mei ChangRoyal Veterinary College, University of London, London, United Kingdom.
Charles A ManireLoggerhead Marinelife Center, Juno Beach, Florida, United States of America.
Samantha ClarkLoggerhead Marinelife Center, Juno Beach, Florida, United States of America.
Nicole I StacyDepartment of Comparative, Diagnostic, and Population Medicine, Aquatic, Amphibian, and Reptile Pathology Program, College of Veterinary Medicine, University of Florida, Gainesville, FL, United States of America.ORCID 0000-0003-4258-4414

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Blood glucose is vital for many physiological pathways and can be quantified by clinical chemistry analyzers and in-house point-of-care (POC) devices. Pre-analytical and analytical factors can influence blood glucose measurements. This project aimed to investigate pre-analytical factors on whole blood and plasma glucose measurements in loggerhead sea turtles (Caretta caretta) by evaluating the effects of storage (refrigeration) up to 48h after sampling and of packed cell volume (PCV) on whole blood glucose analysis by POC glucometer (time series n = 13); and by evaluating the effects of storage (room temperature and refrigeration) on plasma glucose concentrations using a dry slide chemistry analyzer (DCA) at various conditions: immediate processing and delayed plasma separation from erythrocytes at 24h and 48h (time series n = 14). The POC glucometer had overall strong agreement with the DCA (CCC = 0.76, r = 0.84, Cb = 0.90), but consistently overestimated glucose concentrations (mean difference: +0.4 mmol/L). The POC glucometer results decreased significantly over time, resulting in a substantial decline within the first 2h (0.41±0.47 mmol/L; 8±9%) that could potentially alter clinical decisions, thereby highlighting the need for immediate analysis using this method. The effects of PCV on glucose could not be assessed, as the statistical significance was associated with one outlier. Storage method significantly affected plasma glucose measurements using DCA, with room temperature samples resulting in rapid decreases of 3.57±0.89 mmol/L (77±9%) over the first 48h, while refrigerated samples provided consistent plasma glucose results over the same time period (decrease of 0.26±0.23 mmol/L; 6±5%). The results from this study provide new insights into optimal blood sample handling and processing for glucose analysis in sea turtles, show the suitability of the POC glucometer as a rapid diagnostic test, and confirm the reliability of plasma glucose measurements using refrigeration. These findings emphasize the need to consider pre-/analytical factors when interpreting blood glucose results from loggerhead sea turtles.

Indexed as

AnimalsBlood Chemical AnalysisBlood GlucoseFactor Analysis, StatisticalFemalePlasmaReference ValuesReproducibility of ResultsSpecimen HandlingTime FactorsTurtlesBlood Glucose

Identifiers

PMID32126109
PMCPMC7053744

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.