Evidence map›Paper›PMID 32125040›Full record

ArticleMagnetic resonance in medicine2020

Improved compressed sensing and super-resolution of cardiac diffusion MRI with structure-guided total variation.

Irvin Teh, Darryl McClymont, Eric Carruth, Jeffrey Omens, Andrew McCulloch, Jürgen E Schneider

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Irvin TehLeeds Institute of Cardiovascular & Metabolic Medicine, University of Leeds, Leeds, United Kingdom.ORCID 0000-0002-6705-3129
Darryl McClymontPerspectum Diagnostics Ltd, Oxford, United Kingdom.ORCID 0000-0002-2039-7522
Eric CarruthGeisinger Health System, Danville, Pennsylvania.ORCID 0000-0001-8184-8676
Jeffrey OmensDepartment of Medicine, University of California San Diego, La Jolla, California.ORCID 0000-0002-6851-0977
Andrew McCullochDepartment of Medicine, University of California San Diego, La Jolla, California.ORCID 0000-0002-1708-5675
Jürgen E SchneiderLeeds Institute of Cardiovascular & Metabolic Medicine, University of Leeds, Leeds, United Kingdom.ORCID 0000-0003-0999-5684

Funding

MECHANICAL REGULATION OF DILATED CARDIOMYOPATHYR01HL064321 · NHLBI · UNIVERSITY OF CALIFORNIA SAN DIEGO · PI OMENS, JEFFREY H · 2001 to 2004
$1.0M
British Heart Foundation FS/11/50/29038British Heart Foundation PG/13/33/30210British Heart Foundation SI/14/1/30718Medical Research Council MR/M008991/1NHLBI NIH HHS R01 HL064321Wellcome TrustWellcome Trust 090532/Z/09/Z
6 · The paper itself

Abstract

purposeStructure-guided total variation is a recently introduced prior that allows reconstruction of images using knowledge of the location and orientation of edges in a reference image. In this work, we demonstrate the advantages of a variant of structure-guided total variation known as directional total variation (DTV), over traditional total variation (TV), in the context of compressed-sensing reconstruction and super-resolution.

methodsWe compared TV and DTV in retrospectively undersampled ex vivo diffusion tensor imaging and diffusion spectrum imaging data from healthy, sham, and hypertrophic rat hearts.

resultsIn compressed sensing at an undersampling factor of 8, the RMS error of mean diffusivity and fractional anisotropy relative to the fully sampled ground truth were 44% and 20% lower in DTV compared with TV. In super-resolution, these values were 29% and 14%, respectively. Similarly, we observed improvements in helix angle, transverse angle, sheetlet elevation, and sheetlet azimuth. The RMS error of the diffusion kurtosis in the undersampled data relative to the ground truth was uniformly lower (22% on average) with DTV compared to TV.

conclusionAcquiring one fully sampled non-diffusion-weighted image and 10 diffusion-weighted images at 8× undersampling would result in an 80% net reduction in data needed. We demonstrate efficacy of the DTV algorithm over TV in reducing data sampling requirements, which can be translated into higher apparent resolution and potentially shorter scan times. This method would be equally applicable in diffusion MRI applications outside the heart.

Indexed as

Diffusion Magnetic Resonance ImagingDiffusion Tensor ImagingAlgorithmsAnimalsImage Processing, Computer-AssistedMagnetic Resonance ImagingRatsRetrospective Studiescardiac MRIcompressed sensingdiffusion kurtosisdiffusion tensor imagingdirectional total variationsuper-resolution

Identifiers

PMID32125040
PMCPMC8629124

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.