Evidence map›Paper›PMID 32125015›Full record

ArticleMagnetic resonance in medicine2020

Motion-corrected and high-resolution anatomically assisted (MOCHA) reconstruction of arterial spin labeling MRI.

Abolfazl Mehranian, Colm J McGinnity, Radhouene Neji, Claudia Prieto, Alexander Hammers, Enrico De Vita, Andrew J Reader

Open access · hybridAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Abolfazl MehranianDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.ORCID 0000-0003-4584-4453
Colm J McGinnitySchool of Biomedical Engineering and Imaging Sciences, King's College London and King's College London & Guy's and St. Thomas' PET Centre, St. Thomas' Hospital, London, United Kingdom.
Radhouene NejiDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
Claudia PrietoDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
Alexander HammersSchool of Biomedical Engineering and Imaging Sciences, King's College London and King's College London & Guy's and St. Thomas' PET Centre, St. Thomas' Hospital, London, United Kingdom.
Enrico De VitaDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
Andrew J ReaderDepartment of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
King's College London · GBSt Thomas' Hospital · GB

Funding

Medical Research Council MR/N013042/1Wellcome TrustWellcome Trust WT 203148/Z/16/Z
6 · The paper itself

Abstract

purposeA model-based reconstruction framework is proposed for motion-corrected and high-resolution anatomically assisted (MOCHA) reconstruction of arterial spin labeling (ASL) data. In this framework, all low-resolution ASL control-label pairs are used to reconstruct a single high-resolution cerebral blood flow (CBF) map, corrected for rigid-motion, point-spread-function blurring and partial volume effect.

methodsSix volunteers were recruited for CBF imaging using pseudo-continuous ASL labeling, two-shot 3D gradient and spin-echo sequences and high-resolution T

resultsThe MOCHA reconstructions of low-resolution ASL data showed enhanced image quality, particularly in the partition direction. In simulations, both MOCHA and 3D linear regression provided more accurate CBF maps than the standard reconstruction; however, MOCHA resulted in the lowest errors and well delineated the abnormalities. The MOCHA reconstruction of standard-resolution in vivo data showed good agreement with higher-resolution scans requiring 4-times and 9-times longer acquisitions. The MOCHA reconstruction was found to be robust for 4-times-accelerated ASL acquisitions, achieved by reduced control-label pairs or k-space undersampling.

conclusionThe MOCHA reconstruction reduces partial-volume effect by direct reconstruction of CBF maps in the high-resolution space of the corresponding anatomical image, incorporating motion correction and point spread function modeling. Following further evaluation, MOCHA should promote the clinical application of ASL.

Indexed as

BrainImaging, Three-DimensionalCerebrovascular CirculationHumansMagnetic Resonance ImagingSpin LabelsSpin Labelsanatomical priorsarterial spin labelingpartial-volume correctionperfusion MRIreconstruction

Identifiers

PMID32125015
PMCPMC8614125
OpenAlexW3010408806

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.