Evidence map›Paper›PMID 32123950›Full record

ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2021

A minimally invasive, 3D-fluoroscopy-navigation-guided, 3D-controlled pedicle approach in spine surgery: first reliable results and impact on patient safety.

André El Saman, Simon Lars Meier, Ingo Marzi

Open access · hybridAbstract read
In one paragraph

Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 49% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

André El SamanDepartment of Trauma, Hand and Reconstructive Surgery, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany. andre.elsaman@kgu.de.ORCID http://orcid.org/0000-0003-0002-5243
Simon Lars MeierDepartment of Trauma, Hand and Reconstructive Surgery, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany.
Ingo MarziDepartment of Trauma, Hand and Reconstructive Surgery, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany.
Goethe University Frankfurt · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeSafe pedicle screw placement is a daily challenge to every spine surgeon. Introduction of minimally invasive approaches in spinal surgery led to an impaired facility of inspection of the surgical field increasing the importance of intraoperative imaging and navigation. During the past years, we established a minimally invasive, navigated approach in our clinical setting.

methodsWe retrospectively reviewed the accuracy of pedicle approaches in patients treated due to traumatic or osteoporotic fractures, spondylitis/discitis, and tumoral lesions. Guide wires for pedicle screws or kyphoplasty cannulas were inserted in a 3D-navigation-guided, minimally invasive technique. Positioning of the guide wires was verified via 3D-scan, and pedicle screws/kyphoplasty cannulas were then visualized via a.p./lateral radiographs. Accuracy data were compared to a standard navigated open approach control group with indications similar to the MIS-group.

results23 MIS patients were included in this study (25-84 years, mean 70 years) with a total of 154 placed guide wires. Handling of the navigated Jamshidi needle was easy and secure. The guide wires showed correct placement in 151/154 cases. Three wires (1.9%) needed correction of placement after control scan. There were no vascular or neurologic complications due to wire misplacement. In the open-surgery control group, 7/181 screws (3.9%) needed intraoperative correction presenting no significant difference compared to the correction rate of the MIS-group (p = 0.35).

conclusionOur study shows the feasibility and reliability of a navigation-guided, minimally invasive pedicle approach in the clinical setting. Therefore, reduced morbidity due to minimized approaches can be combined with higher accuracy of navigated pedicle screw/kyphoplasty cannula placement improving patient safety.

Indexed as

Pedicle ScrewsSpinal FusionSurgery, Computer-AssistedFluoroscopyHumansImaging, Three-DimensionalLumbar VertebraePatient SafetyReproducibility of ResultsRetrospective Studies3DAccuracyMinimally invasiveMISNavigationPedicle screwSpine surgery

Identifiers

PMID32123950
PMCPMC8187224
OpenAlexW3009234321

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.