Evidence map›Paper›PMID 32121672›Full record

ArticleSensors (Basel, Switzerland)2020

Sleep Apnea Detection with Polysomnography and Depth Sensors.

Martin Schätz, Aleš Procházka, Jiří Kuchyňka, Oldřich Vyšata

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.4field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 32 citations in OpenAlex.

  1. Review
  2. Key Vital Signs Monitor Based on MIMO Radar.Sensors (Basel, Switzerland) · 2025
    Article
  3. Noncontact respiratory monitoring during sleep: comparison of the touchless flow signal with respiratory inductance plethysmography flow (RIPJournal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2025
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Review
  11. Review
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Martin SchätzUniversity of Chemistry and Technology in Prague, Department of Computing and Control Engineering, 166 28 Prague 6, Czech Republic.ORCID 0000-0003-0931-4017
Aleš ProcházkaUniversity of Chemistry and Technology in Prague, Department of Computing and Control Engineering, 166 28 Prague 6, Czech Republic.
Jiří KuchyňkaCharles University, University Hospital Hradec Králové, Faculty of Medicine in Hradec Králové, Department of Neurology, 500 05 Hradec Králové, Czech Republic.
Oldřich VyšataUniversity of Chemistry and Technology in Prague, Department of Computing and Control Engineering, 166 28 Prague 6, Czech Republic.
Charles University · CZUniversity of Chemistry and Technology, Prague · CZ

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper is devoted to proving two goals, to show that various depth sensors can be used to record breathing rate with the same accuracy as contact sensors used in polysomnography (PSG), in addition to proving that breathing signals from depth sensors have the same sensitivity to breathing changes as in PSG records. The breathing signal from depth sensors can be used for classification of sleep [d=R2]apneaapnoa events with the same success rate as with PSG data. The recent development of computational technologies has led to a big leap in the usability of range imaging sensors. New depth sensors are smaller, have a higher sampling rate, with better resolution, and have bigger precision. They are widely used for computer vision in robotics, but they can be used as non-contact and non-invasive systems for monitoring breathing and its features. The breathing rate can be easily represented as the frequency of a recorded signal. All tested depth sensors (MS Kinect v2, RealSense SR300, R200, D415 and D435) are capable of recording depth data with enough precision in depth sensing and sampling frequency in time (20-35 frames per second (FPS)) to capture breathing rate. The spectral analysis shows a breathing rate between 0.2 Hz and 0.33 Hz, which corresponds to the breathing rate of an adult person during sleep. To test the quality of breathing signal processed by the proposed workflow, a neural network classifier (simple competitive NN) was trained on a set of 57 whole night polysomnographic records with a classification of sleep [d=R2]apneaapnoas by a sleep specialist. The resulting classifier can mark all [d=R2]apneaapnoa events with 100% accuracy when compared to the classification of a sleep specialist, which is useful to estimate the number of events per hour. [d=R2]When compared to the classification of polysomnographic breathing signal segments by a sleep specialistand, which is used for calculating length of the event, the classifier has an [d=R1] F 1 score of 92.2%Accuracy of 96.8% (sensitivity 89.1% and specificity 98.8%). The classifier also proves successful when tested on breathing signals from MS Kinect v2 and RealSense R200 with simulated sleep [d=R2]apneaapnoa events. The whole process can be fully automatic after implementation of automatic chest area segmentation of depth data.

Indexed as

AdultFemaleHumansMaleMiddle AgedPolysomnographyRespirationRespiratory RateSensitivity and SpecificitySignal Processing, Computer-AssistedSleepSleep Apnea Syndromesbreathing analysiscomputational intelligencedepth sensorshuman-machine interactionimage processingsignal processing

Identifiers

PMID32121672
PMCPMC7085736
OpenAlexW3009923056

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.