ArticleSensors (Basel, Switzerland)2020
A Novel Classification Method for a Driver's Cognitive Stress Level by Transferring Interbeat Intervals of the ECG Signal to Pictures.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Human-Centric Cognitive State Recognition Using Physiological Signals: A Systematic Review of Machine Learning Strategies Across Application Domains.Sensors (Basel, Switzerland) · 2025Pooled it
- Mental Stress Detection Using Physiological Sensors and Artificial Intelligence: A Review.Sensors (Basel, Switzerland) · 2026Review
- Machine Learning, Deep Learning, and Data Preprocessing Techniques for Detecting, Predicting, and Monitoring Stress and Stress-Related Mental Disorders: Scoping Review.JMIR mental health · 2024Article
- Driver Drowsiness Multi-Method Detection for Vehicles with Autonomous Driving Functions.Sensors (Basel, Switzerland) · 2024Article
- Prediction of the Maturity of Greenhouse Grapes Based on Imaging Technology.Plant phenomics (Washington, D.C.) · 2022Article
- Real-Time Stress Level Feedback from Raw Ecg Signals for Personalised, Context-Aware Applications Using Lightweight Convolutional Neural Network Architectures.Sensors (Basel, Switzerland) · 2021Article
- Vital Sign Monitoring in Car Seats Based on Electrocardiography, Ballistocardiography and Seismocardiography: A Review.Sensors (Basel, Switzerland) · 2020Review
- Stress Classification Using Photoplethysmogram-Based Spatial and Frequency Domain Images.Sensors (Basel, Switzerland) · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
In this study, a novel classification method for a driver's cognitive stress level was proposed, whereby the interbeat intervals extracted from an electrocardiogram (ECG) signal were transferred to pictures, and a convolution neural network (CNN) was used to train the pictures to classify a driver's cognitive stress level. First, we defined three levels of tasks and collected the ECG signal of the driver at different cognitive stress levels by designing and performing a driving simulation experiment. We extracted the interbeat intervals and converted them to pictures according to the number of consecutive interbeat intervals in each picture. Second, the CNN model was used to train the data set to recognize the cognitive stress levels. Classification accuracies of 100%, 91.6% and 92.8% were obtained for the training set, validation set and test set, respectively, and were compared with those the BP neural network. Last, we discussed the influence of the number of interbeat intervals in each picture on the performance of the proposed classification method. The results showed that the performance initially improved with an increase in the number of interbeat intervals. A downward trend was observed when the number exceeded 40, and when the number was 40, the model performed best with the highest accuracy (98.79%) and a relatively low relative standard deviation (0.019).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.