Evidence map›Paper›PMID 32119869›Full record

ArticleExperimental eye research2020

Contrast-enhanced plane-wave ultrasound imaging of the rat eye.

Raksha Urs, Jeffrey A Ketterling, Gulgun Tezel, Ronald H Silverman

Open access · greenAbstract read
In one paragraph

Article in Experimental eye research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Raksha UrsDepartment of Ophthalmology, Columbia University Irving Medical Center, New York, NY, USA.
Jeffrey A KetterlingF.L. Lizzi Center for Bioengineering, Riverside Research, New York, NY, USA.
Gulgun TezelDepartment of Ophthalmology, Columbia University Irving Medical Center, New York, NY, USA.
Ronald H SilvermanDepartment of Ophthalmology, Columbia University Irving Medical Center, New York, NY, USA. Electronic address: rs3072@cumc.columbia.edu.
Columbia University Irving Medical Center · USRiverside Research Institute · US

Funding

Instrumentation, Fabrication, and Design CoreP30EY019007 · NEI · COLUMBIA UNIVERSITY HEALTH SCIENCES · PI Xin Zhang · 2010 to 2026
$12.9M
In utero mouse embryo phenotyping with high-frequency ultrasoundR01EB022950 · NIBIB · RIVERSIDE RESEARCH INSTITUTE · PI KETTERLING, JEFFREY, TURNBULL, DANIEL H · 2016 to 2019
$2.8M
Ocular hemodynamics of rat model of glaucomaR01EY028550 · NEI · COLUMBIA UNIVERSITY HEALTH SCIENCES · PI SILVERMAN, RONALD H · 2018 to 2021
$1.8M
Fine-resolution mapping of micro vasculature after placental transport of acoustic nanodropsR21HD097485 · NICHD · RIVERSIDE RESEARCH INSTITUTE · PI KETTERLING, JEFFREY · 2019 to 2020
$442k
NEI NIH HHS P30 EY019007NEI NIH HHS R01 EY028550NIBIB NIH HHS R01 EB022950NICHD NIH HHS R21 HD097485
6 · The paper itself

Abstract

Preclinical imaging, especially of rodent models, plays a major role in experimental ophthalmology. Our aim was to determine if ultrasound can be used to visualize and measure flow dynamics in the retrobulbar vessels supplying and draining the eye and the potential of contrast microbubbles to provide image and measurement enhancement. To accomplish this, we used a 128-element, 18 MHz linear array ultrasound probe and performed plane-wave imaging of the eyes of Sprague Dawley rats. Compound images were acquired by emitting unfocused wavefronts at multiple angles and combining echo data from all angles to form individual B-scans. Multiple imaging sequences were utilized, compounding up to six angles, with imaging rate of up to 3000 compound B-scans per second and sequence durations from 1.5 to 180 s. Data were acquired before and after intravenous introduction of contrast microbubbles. We found the total power of the Doppler signal in the image plane to increase approximately 20 fold after injection of contrast, followed by an exponential decay to baseline in about 90 s, The best-fit time constant of the decay averaged 41 s. While major vessels and the retinal/choroidal complex were evident pre-contrast, they were dramatically enhanced with contrast present, with details such as choroidal arterioles seen only with contrast. Ocular arteriovenous transit time determined from comparative enhancement curves in arteries and veins was approximately 0.2 s. In conclusion, plane wave ultrasound, especially with enhancement by contrast microbubbles, offers a means for the study of ocular hemodynamics using the rat eye as a model.

Indexed as

Phantoms, ImagingAnimalsContrast MediaModels, AnimalOphthalmic ArteryOrbitRatsRats, Sprague-DawleyRegional Blood FlowUltrasonographyContrast MediaContrast agentMicrobubbleOcular blood flowPlane-waveRat eyeUltrasound

Identifiers

PMID32119869
PMCPMC7113110
OpenAlexW3008469317

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.