ArticleJAMA network open2020
Evaluation of Combined Artificial Intelligence and Radiologist Assessment to Interpret Screening Mammograms.
Article in JAMA network open, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 176 papers, 6 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
176 citing papers in PubMed, 6 syntheses or guidelines pooled it.
- Frequency and characteristics of errors by artificial intelligence (AI) in reading screening mammography: a systematic review.Breast cancer research and treatment · 2024Pooled it
- Natural language processing for mental health interventions: a systematic review and research framework.Translational psychiatry · 2023Pooled it
- Unassisted Clinicians Versus Deep Learning-Assisted Clinicians in Image-Based Cancer Diagnostics: Systematic Review With Meta-analysis.Journal of medical Internet research · 2023Pooled it
- Independent External Validation of Artificial Intelligence Algorithms for Automated Interpretation of Screening Mammography: A Systematic Review.Journal of the American College of Radiology : JACR · 2022Pooled it
- Machine Learning for Workflow Applications in Screening Mammography: Systematic Review and Meta-Analysis.Radiology · 2022Pooled it
- Use of artificial intelligence for image analysis in breast cancer screening programmes: systematic review of test accuracy.BMJ (Clinical research ed.) · 2021Pooled it
- Triaging mammography with artificial intelligence: an implementation study.Breast cancer research and treatment · 2025Trial
- Optimizing AI-assisted decision-making in mammography screening: focusing on uncertainties.Insights into imaging · 2026Article
- Ten Years of Artificial Intelligence in Screening Mammography: A Systematic Review and Meta-Analysis of Diagnostic Accuracy and Clinical Implementation (Literature Published 2015-2025).Diagnostics (Basel, Switzerland) · 2026Review
- Artificial intelligence in oncology: linking biological discovery to clinical utility.Molecular cancer · 2026Review
- Long-term prognostic implications of AI-detected versus AI-undetected breast cancers on mammography: a propensity score-matched analysis.European radiology · 2026Article
- AI-CAD for diagnostic mammography: comparison to radiologists according to different indications.European radiology · 2026Article
- A review of application of Artificial Intelligence in breast cancer detection and treatment.Discover oncology · 2026Review
- Viewpoint on the Consequences and Mitigation of Cognitive Bias in the Radiological Interpretation of Breast Cancer Imaging Using Artificial Intelligence.JMIR medical informatics · 2026Review
- Bridging Pixels and Practice: AI-Assisted Mammography as a Next-Generation Diagnostic Strategy for Breast Cancer Screening.Diagnostics (Basel, Switzerland) · 2026Review
- Evaluation of the Diagnostic Accuracy of Comercially Available AI-CAD Solution in Mammography Screening in Mexican Women (Mammo-MX Database).Diagnostics (Basel, Switzerland) · 2026Article
- Combined use of two artificial intelligence-based algorithms for mammography triaging: a retrospective simulation study.European radiology · 2026Article
- Artificial intelligence for breast cancer management.Communications medicine · 2026Review
- Dual-modality CAD for breast cancer screening: dealing with discordant diagnosis between mammography and tomography.Frontiers in oncology · 2026Article
- The plasma nanoDSF denaturation profiles predict the presence of breast cancer.Journal of translational medicine · 2025Article
116 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
- Erratum issued
Authors and funding
74 authors.
Funding
Abstract
Importance: Mammography screening currently relies on subjective human interpretation. Artificial intelligence (AI) advances could be used to increase mammography screening accuracy by reducing missed cancers and false positives. Objective: To evaluate whether AI can overcome human mammography interpretation limitations with a rigorous, unbiased evaluation of machine learning algorithms. Design, Setting, and Participants: In this diagnostic accuracy study conducted between September 2016 and November 2017, an international, crowdsourced challenge was hosted to foster AI algorithm development focused on interpreting screening mammography. More than 1100 participants comprising 126 teams from 44 countries participated. Analysis began November 18, 2016. Main Outcomes and Measurements: Algorithms used images alone (challenge 1) or combined images, previous examinations (if available), and clinical and demographic risk factor data (challenge 2) and output a score that translated to cancer yes/no within 12 months. Algorithm accuracy for breast cancer detection was evaluated using area under the curve and algorithm specificity compared with radiologists' specificity with radiologists' sensitivity set at 85.9% (United States) and 83.9% (Sweden). An ensemble method aggregating top-performing AI algorithms and radiologists' recall assessment was developed and evaluated. Results: Overall, 144 231 screening mammograms from 85 580 US women (952 cancer positive ≤12 months from screening) were used for algorithm training and validation. A second independent validation cohort included 166 578 examinations from 68 008 Swedish women (780 cancer positive). The top-performing algorithm achieved an area under the curve of 0.858 (United States) and 0.903 (Sweden) and 66.2% (United States) and 81.2% (Sweden) specificity at the radiologists' sensitivity, lower than community-practice radiologists' specificity of 90.5% (United States) and 98.5% (Sweden). Combining top-performing algorithms and US radiologist assessments resulted in a higher area under the curve of 0.942 and achieved a significantly improved specificity (92.0%) at the same sensitivity. Conclusions and Relevance: While no single AI algorithm outperformed radiologists, an ensemble of AI algorithms combined with radiologist assessment in a single-reader screening environment improved overall accuracy. This study underscores the potential of using machine learning methods for enhancing mammography screening interpretation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.