Evidence map›Paper›PMID 32106566›Full record

ArticleSensors (Basel, Switzerland)2020

Graphene-Oxide-Based Electrochemical Sensors for the Sensitive Detection of Pharmaceutical Drug Naproxen.

Lanting Qian, Antony Raj Thiruppathi, Reem Elmahdy, Joshua van der Zalm, Aicheng Chen

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
7.4field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed, 119 citations in OpenAlex.

  1. Buttressing ligand-binding pockets in de novo designed NTF2-like domains.Protein science : a publication of the Protein Society · 2025
    Article
  2. Review
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Metal-Based Nanomaterials for the Sensing of NSAIDS.Nanomaterials (Basel, Switzerland) · 2024
    Article
  9. Article
  10. Review
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Lanting QianElectrochemical Technology Centre, Department of Chemistry, University of Guelph, 50 Stone Road East, Guelph, Ontario N1G 2W1, Canada.
Antony Raj ThiruppathiElectrochemical Technology Centre, Department of Chemistry, University of Guelph, 50 Stone Road East, Guelph, Ontario N1G 2W1, Canada.ORCID 0000-0001-7594-9681
Reem ElmahdyElectrochemical Technology Centre, Department of Chemistry, University of Guelph, 50 Stone Road East, Guelph, Ontario N1G 2W1, Canada.
Joshua van der ZalmElectrochemical Technology Centre, Department of Chemistry, University of Guelph, 50 Stone Road East, Guelph, Ontario N1G 2W1, Canada.
Aicheng ChenElectrochemical Technology Centre, Department of Chemistry, University of Guelph, 50 Stone Road East, Guelph, Ontario N1G 2W1, Canada.
University of Guelph · CA

Funding

Natural Sciences and Engineering Research Council of Canada RGPIN-2015-06248
6 · The paper itself

Abstract

Here we report on a selective and sensitive graphene-oxide-based electrochemical sensor for the detection of naproxen. The effects of doping and oxygen content of various graphene oxide (GO)-based nanomaterials on their respective electrochemical behaviors were investigated and rationalized. The synthesized GO and GO-based nanomaterials were characterized using a field-emission scanning electron microscope, while the associated amounts of the dopant heteroatoms and oxygen were quantified using x-ray photoelectron spectroscopy. The electrochemical behaviors of the GO, fluorine-doped graphene oxide (F-GO), boron-doped partially reduced graphene oxide (B-rGO), nitrogen-doped partially reduced graphene oxide (N-rGO), and thermally reduced graphene oxide (TrGO) were studied and compared via cyclic voltammetry (CV) and differential pulse voltammetry (DPV). It was found that GO exhibited the highest signal for the electrochemical detection of naproxen when compared with the other GO-based nanomaterials explored in the present study. This was primarily due to the presence of the additional oxygen content in the GO, which facilitated the catalytic oxidation of naproxen. The GO-based electrochemical sensor exhibited a wide linear range (10 mM-1 mM), a high sensitivity (0.60 µAµM

Indexed as

Biosensing TechniquesElectrochemical TechniquesElectrodesGraphiteHalogenationNaproxenOxidation-ReductionPharmaceutical PreparationsPhotoelectron SpectroscopySurface Propertiesgraphene oxideGraphiteNaproxenPharmaceutical Preparationsdifferential pulse voltammetrydopingelectrochemical sensorgraphene oxideKeywords:  naproxenpharmaceutical drug

Identifiers

PMID32106566
PMCPMC7085571
OpenAlexW3007149813

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.