How to avoid unnecessary RF applications in cavo-tricuspid isthmus: common atrial flutter ablation using 8-mm-tip mini-electrode-equipped catheter.

Bartłomiej Jacek Bińkowski, Tomasz Kucejko, Artur Łagodziński, Andrzej Lubiński

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Bartłomiej Jacek BińkowskiDepartment of Interventional Cardiology and Cardiac Arrhythmias, University Clinical Hospital Military Memorial Medical Academy - Central Veterans' Hospital in Lodz, Medical University of Lodz, Żeromskiego 113, 90-549, Łódź, Poland. bartekbinkowski@gmail.com.ORCID http://orcid.org/0000-0002-1697-223X
Tomasz KucejkoDepartment of Interventional Cardiology and Cardiac Arrhythmias, University Clinical Hospital Military Memorial Medical Academy - Central Veterans' Hospital in Lodz, Medical University of Lodz, Żeromskiego 113, 90-549, Łódź, Poland.
Artur ŁagodzińskiDepartment of Interventional Cardiology and Cardiac Arrhythmias, University Clinical Hospital Military Memorial Medical Academy - Central Veterans' Hospital in Lodz, Medical University of Lodz, Żeromskiego 113, 90-549, Łódź, Poland.
Andrzej LubińskiDepartment of Interventional Cardiology and Cardiac Arrhythmias, University Clinical Hospital Military Memorial Medical Academy - Central Veterans' Hospital in Lodz, Medical University of Lodz, Żeromskiego 113, 90-549, Łódź, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeEight-millimeter-tip ablation catheters are characterized by poor mapping resolution as they depend on electrode size and spacing. IntellaTip MiFi XP 8-mm (Boston Scientific) catheters offer high mapping resolution due to 3 mini-electrodes (ME) located at the distal tip of the catheter and are dedicated for cavo-tricuspid isthmus (CTI) radiofrequency ablation (RFA). The aim of the study was to evaluate the usefulness, effectiveness and safety of novel IntellaTip MiFi XP catheter for CTI RFA and its ability to localize anatomical structures of the heart.

methodsThe study included 10 patients referred for atrial flutter ablation. The 3D mapping system EnSite Velocity was utilized for catheter visualization. The ME signals were used for tricuspid annulus visualization, RF delivery effectiveness assessment defined as ME signal attenuation, and localization of the gaps in the ablation line. The use of ME signals for TV annulus localization resulted in a 13.9 mm (35.5 ± 4.8 mm vs 49.4 ± 7.8 mm; p < 0.01) shorter ablation line in comparison with the potential ablation line designed using standard bipol. The ablation endpoint, bidirectional block, was achieved in all 10 cases (100%) and lasted for at least 15 min after the last RF delivery. The ablation endpoint was reached after 5.1 ± 1.67 RF applications. The total RF time was 220 ± 61 s. Total procedure time was 66 ± 13.5 min, fluoroscopy time 3.92 ± 4.21 min, and total fluoroscopy dose 40.3 ± 56.5 mGy.

resultsIn 3 out of 10 cases, there was a need of filling the gap with 1-2 additional applications after the first linear lesion set. No additional RF applications were required at the annular end of the ablation line. The indirect comparison with previously conducted studies using a standard 8-mm ablation catheter shows that the studied catheter has at least the same or even better performance.

conclusionsThe use of the novel IntellaTip MiFi XP may help to avoid unnecessary RF application especially at the annular part of cavo-tricuspid isthmus and enables a purely electrophysiological approach to atrial flutter ablation, as high-resolution ME signals help to understand local electrophysiological phenomena.

Indexed as

Atrial FlutterCatheter AblationCathetersElectrodesEquipment DesignHumansTreatment OutcomeAtrial flutter ablationCavo-tricuspid isthmus ablationHigh-resolution mappingMini-electrodes