Evidence map›Paper›PMID 32097828›Full record

ArticleHearing research2020

Forward masking patterns by low and high-rate stimulation in cochlear implant users: Differences in masking effectiveness and spread of neural excitation.

Ning Zhou, Lixue Dong, Susannah Dixon

Abstract readComparative Study
In one paragraph

Article in Hearing research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Ning ZhouDepartment of Communication Sciences and Disorders, East Carolina University, Greenville, NC, 27834, USA. Electronic address: zhoun@ecu.edu.
Lixue DongDepartment of Communication Sciences and Disorders, East Carolina University, Greenville, NC, 27834, USA.
Susannah DixonDepartment of Communication Sciences and Disorders, East Carolina University, Greenville, NC, 27834, USA.

Funding

Assessing non-invasive measures of neural health in cochlear implant users and the clinical implicationsR03DC014771 · NIDCD · EAST CAROLINA UNIVERSITY · PI ZHOU, NING · 2016 to 2018
$432k
NIDCD NIH HHS R03 DC014771
6 · The paper itself

Abstract

The goal of the present study was to compare forward masking patterns by stimulation of low and high rates in cochlear implant users. Postlingually deafened Cochlear Nucleus® device users participated in the study. In experiment 1, two maskers of different rates (250 and 1000 pulses per second) were set at levels that produced equal masking for a probe presented at the same electrode as the maskers. This aligned the two masking functions at the on-site probe location. Then their forward masking patterns for the far probes were compared. Results showed that slope of the masked probe-threshold decay as a function of probe-masker separation was steeper for the high-rate than the low-rate masker. A linear model indicated that this difference in spread of neural excitation (SOE) was accounted for by two factors that were not correlated with each other. One factor was that the low-rate masker required a considerably higher current level to be equally effective in masking as the high-rate masker. The second factor was the effect of stimulation rate on loudness, i.e., integration of multiple pulses. This was consistent with our hypothesis that if an increase in stimulation rate does not result in an increased total neural response, then it is unlikely that the change in rate would change spatial distribution of the neural activity. Interestingly, the difference in masking effectiveness of the maskers predicted subjects' speech recognition. Poorer performers were those who showed more comparable masking effects by maskers of different rates. The difference in the masking effectiveness may indirectly measure the auditory neurons' excitability, which predicts speech recognition. In experiment 2, SOE of the high-rate and low-rate maskers were compared at a level that is clinically relevant, i.e., equal loudness. At equal loudness, high-rate stimulation not only produced an overall greater amount of forward masking, but also a shallower decay of masking with probe-masker separation (wider SOE), compared to low rate. The difference in SOE was the opposite to the findings from experiment 1. Whether the maskers were calibrated for equal masking or loudness, the absolute current level was always higher for the low-rate masker, which suggests that the SOE patterns cannot be explained by current spread alone. The fact that high-rate stimulation produced greater masking and wider SOE at equal loudness may explain why using high stimulation rates has not produced consistent benefits for speech recognition, and why lowering stimulation rate from the manufacturer's default sometimes results in improved speech recognition for subjects.

Indexed as

Cochlear ImplantsPerceptual MaskingSpeech PerceptionAcoustic StimulationAgedCochleaCochlear ImplantationDeafnessElectric StimulationFemaleHearingHumansLoudness PerceptionMaleMiddle AgedNoiseForward maskingHigh-rate stimulationLow-rate stimulationMasking effectivenessSpeech recognition

Identifiers

PMID32097828
PMCPMC7080592

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.