Evidence map›Paper›PMID 32096381›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2020

[Fluid-solid coupling numerical simulation on ideal porous structure of rat alveolar bone].

Rui Luo, Zhenda Zhao, Huijie Leng, Bo Huo

Open access · greenAbstract read
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact, top 98% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 0 citations in OpenAlex.

  1. [Relationship between fluid shear stress in alveolar bone under orthodontic forces and bone remodeling rate].Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology · 2025
    Article
  2. [Design of nonlinear locking mechanism for shape memory alloy archwire of miniature orthodontic device].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Rui LuoBiomechanics Lab, Department of Mechanics, School of Aerospace Engineering, Beijing Institute of Technology, Beijing 100081, P.R.China.
Zhenda ZhaoDepartment of Orthopaedics, Peking University Third Hospital, Beijing 100191, P.R.China.
Huijie LengDepartment of Orthopaedics, Peking University Third Hospital, Beijing 100191, P.R.China.
Bo HuoBiomechanics Lab, Department of Mechanics, School of Aerospace Engineering, Beijing Institute of Technology, Beijing 100081, P.R.China.
Beijing Institute of Technology · CNPeking University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fluid shear stress (FSS) caused by interstitial fluid flow within trabecular bone cavities under mechanical loading is the key factor of stimulating biological response of bone cells. Therefore, to investigate the FSS distribution within cancellous bone is important for understanding the transduction process of mechanical forces within alveolar bone and the regulatory mechanism at cell level during tooth development and orthodontics. In the present study, the orthodontic tooth movement experiment on rats was first performed. Finite element model of tooth-periodontal ligament-alveolar bone based on micro computed tomography (micro-CT) images was established and the strain field in alveolar bone was analyzed. An ideal model was constructed mimicking the porous structure of actual rat alveolar bone. Fluid flow in bone was predicted by using fluid-solid coupling numerical simulation. Dynamic occlusal loading with orthodontic tension loading or compression loading was applied on the ideal model. The results showed that FSS on the surface of the trabeculae along occlusal direction was higher than that along perpendicular to occlusal direction, and orthodontic force has little effect on FSS within alveolar bone. This study suggests that the orientation of occlusal loading can be changed clinically by adjusting the shape of occlusal surface, then FSS with different level could be produced on trabecular surface, which further activates the biological response of bone cells and finally regulates the remodeling of alveolar bone.

Indexed as

PorosityTooth Movement TechniquesAlveolar ProcessAnimalsFinite Element AnalysisPeriodontal LigamentRatsStress, MechanicalX-Ray Microtomographyalveolar bonefluid shear stressfluid-solid couplingporous structuretrabecula

Identifiers

PMID32096381
PMCPMC9927654
OpenAlexW3012803867

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.