Evidence map›Paper›PMID 32095551›Full record

ArticleTechnical innovations & patient support in radiation oncology2019

Breath-hold versus mid-ventilation in SBRT of adrenal metastases.

Melissa de Kuijer, Jaap van Egmond, E Kouwenhoven, Dieke Bruijn-Krist, Heleen Ceha, Mirjam Mast

Open access · goldAbstract read
In one paragraph

Article in Technical innovations & patient support in radiation oncology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Evaluation of internal target volume of abdominal tumors using cine-MRI.Journal of applied clinical medical physics · 2025
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Melissa de KuijerHaaglanden Medical Center, Department of Radiotherapy, Leidschendam, the Netherlands.
Jaap van EgmondHaaglanden Medical Center, Department of Medical Physics, Leidschendam, the Netherlands.
E KouwenhovenHaaglanden Medical Center, Department of Medical Physics, Leidschendam, the Netherlands.
Dieke Bruijn-KristHaaglanden Medical Center, Department of Radiotherapy, Leidschendam, the Netherlands.
Heleen CehaHaaglanden Medical Center, Department of Radiotherapy, Leidschendam, the Netherlands.
Mirjam MastHaaglanden Medical Center, Department of Radiotherapy, Leidschendam, the Netherlands.
Medisch Centrum Haaglanden · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo improve local control in radiotherapy of adrenal metastases precise dose delivery without increasing toxicity is vital. Decreasing the Clinical Target Volume (CTV) - Planning Target Volume (PTV) margins by reducing breathing movement can achieve this. Few data were published concerning the effect of a breath-hold technique. This study investigates the potential of Active Breathing Control (ABC) to limit adrenal breathing movement and reduce CTV-PTV margins.

methodsWe compared adrenal gland movement in free-breathing, making use of the Mid-ventilation (MidV) technique, and with ABC. The coordinates of the adrenal glands obtained on ten phases of a free breathing 4D-CT and on several repeat inspiration ABC CT-scans were measured. Separate coordinates, the random margin component and the margin vector norm were computed and compared between the two techniques.

resultsWe compared the two techniques in 11 patients (21 adrenal glands) and found the largest movement in the Z-direction, with values of 8.7 ± 4.2 mm for MidV and 2.4 ± 1.5 mm for ABC. In 71% of the cases ABC resulted in a smaller margin component than MidV, although non-significant (p ≥ 0.4).

conclusionMovement of the adrenal gland is largest in the Z-direction. The mean difference in the margin vector norm between both techniques was small with large variations over the patient group, the clinical effect of these differences is unknown. Applying an individualised motion management strategy could be beneficial. If a peak-to-peak amplitude above 15 mm in the Z-direction is observed in the MidV scan we advise to examine if a breath-hold technique could reduce margins.

Indexed as

4D-CT-scanAdrenal SBRTInspiration breath-holdMargin

Identifiers

PMID32095551
PMCPMC7033782
OpenAlexW2994695460

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.