ArticleApplied sciences (Basel, Switzerland)2019
Photoacoustic Tomography with a Ring Ultrasound Transducer: A Comparison of Different Illumination Strategies.
Article in Applied sciences (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 19 citations in OpenAlex.
- Wavelength-dependent error minimization for quantitative spectroscopic photoacoustic tomography with a ring-array system.Zeitschrift fur medizinische Physik · 2023Article
- Niche preclinical and clinical applications of photoacoustic imaging with endogenous contrast.Photoacoustics · 2023Review
- Recent Advances in Flexible Ultrasonic Transducers: From Materials Optimization to Imaging Applications.Micromachines · 2023Review
- Dual-Wavelength Photoacoustic Computed Tomography with Piezoelectric Ring-Array Transducer for Imaging of Indocyanine Green Liposomes Aggregation in Tumors.Micromachines · 2022Article
- Endocavity ultrasound and photoacoustic system for fetal and maternal imaging: design, implementation, andJournal of medical imaging (Bellingham, Wash.) · 2021Article
- Review of consensus test methods in medical imaging and current practices in photoacoustic image quality assessment.Journal of biomedical optics · 2021Review
- Model-based optical and acoustical compensation for photoacoustic tomography of heterogeneous mediums.Photoacoustics · 2021Article
- Optimizing Irradiation Geometry in LED-Based Photoacoustic Imaging with 3D Printed Flexible and Modular Light Delivery System.Sensors (Basel, Switzerland) · 2020Article
- Photoacoustic Imaging to Track Magnetic-manipulated Micro-Robots in Deep Tissue.Sensors (Basel, Switzerland) · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
Photoacoustic (PA) imaging is a methodology that uses the absorption of short laser pulses by endogenous or exogenous chromophores within human tissue, and the subsequent generation of acoustic waves acquired by an ultrasound (US) transducer, to form an image that can provide functional and molecular information. Amongst the various types of PA imaging, PA tomography (PAT) has been proposed for imaging pathologies such as breast cancer. However, the main challenge for PAT imaging is the deliverance of sufficient light energy horizontally through an imaging cross-section as well as vertically. In this study, three different illumination methods are compared for a full-ring ultrasound (US) PAT system. The three distinct illumination setups are full-ring, diffused-beam, and point source illumination. The full-ring system utilizes a cone mirror and parabolic reflector to create the ringed-shaped beam for PAT, while the diffuse scheme uses a light diffuser to expand the beam, which illuminates tissue-mimicking phantoms. The results indicate that the full-ring illumination is capable of providing a more uniform fluence irrespective of the vertical depth of the imaged cross-section, while the point source and diffused illumination methods provide a higher fluence at regions closer to the point of entry, which diminishes with depth. In addition, a set of experiments was conducted to determine the optimum position of ring-illumination with respect to the position of the acoustic detectors to achieve the highest signal-to-noise ratio.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.