Design and Evaluation of Magnetic Hall Effect Tactile Sensors for Use in Sensorized Splints.

Dominic Jones, Lefan Wang, Ali Ghanbari, Vasiliki Vardakastani, Angela E Kedgley, Matthew D Gardiner, Tonia L Vincent, Peter R Culmer, Ali Alazmani

Open access · goldAbstract readEvaluation Study
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 40 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Dominic JonesSchool of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK.
Lefan WangSchool of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK.ORCID 0000-0002-4123-4159
Ali GhanbariSchool of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK.ORCID 0000-0003-1087-8426
Vasiliki VardakastaniDepartment of Bioengineering, Imperial College London, London SW7 2AZ, UK.ORCID 0000-0002-0781-8759
Angela E KedgleyDepartment of Bioengineering, Imperial College London, London SW7 2AZ, UK.ORCID 0000-0001-7282-6651
Matthew D GardinerKennedy Institute of Rheumatology, University of Oxford, Oxford OX3 7FY, UK.
Tonia L VincentKennedy Institute of Rheumatology, University of Oxford, Oxford OX3 7FY, UK.
Peter R CulmerSchool of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK.
Ali AlazmaniSchool of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK.ORCID 0000-0001-8983-173X
University of Leeds · GBImperial College London · GBUniversity of Oxford · GB

Funding

Dunhill Medical Trust R595/0717The Dunhill Medical Trust R595/0717
6 · The paper itself

Abstract

Splinting techniques are widely used in medicine to inhibit the movement of arthritic joints. Studies into the effectiveness of splinting as a method of pain reduction have generally yielded positive results, however, no significant difference has been found in clinical outcomes between splinting types. Tactile sensing has shown great promise for the integration into splinting devices and may offer further information into applied forces to find the most effective methods of splinting. Hall effect-based tactile sensors are of particular interest in this application owing to their low-cost, small size, and high robustness. One complexity of the sensors is the relationship between the elastomer geometry and the measurement range. This paper investigates the design parameters of Hall effect tactile sensors for use in hand splinting. Finite element simulations are used to locate the areas in which sensitivity is high in order to optimise the deflection range of the sensor. Further simulations then investigate the mechanical response and force ranges of the elastomer layer under loading which are validated with experimental data. A 4 mm radius, 3 mm-thick sensor is identified as meeting defined sensing requirements for range and sensitivity. A prototype sensor is produced which exhibits a pressure range of 45 kPa normal and 6 kPa shear. A proof of principle prototype demonstrates how this can be integrated to form an instrumented splint with multi-axis sensing capability and has the potential to inform clinical practice for improved splinting.

Indexed as

Magnetic PhenomenaOrthopedic EquipmentSplintsCalibrationComputer SimulationElastomersEquipment DesignFinite Element AnalysisTouchElastomerscalibrationforce sensorsHall effect sensorhand splinthyperelastic elastomermagnetic fieldsilicone rubbersoft sensingtactile sensors

Identifiers

PMID32092865
PMCPMC7070306
OpenAlexW3007174652

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.