ArticlePloS one2020
Real-time feedback improves chest compression quality in out-of-hospital cardiac arrest: A prospective cohort study.
Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 20 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 3 syntheses or guidelines pooled it.
- Designing Chinese hospital emergency departments to leverage artificial intelligence-a systematic literature review on the challenges and opportunities.Frontiers in medical technology · 2024Pooled it
- The impact of cognitive aids on resuscitation performance in in-hospital cardiac arrest scenarios: a systematic review and meta-analysis.Internal and emergency medicine · 2022Pooled it
- Defining and evaluating the Hawthorne effect in primary care, a systematic review and meta-analysis.Frontiers in medicine · 2022Pooled it
- Comparison of real-time feedback and debriefing by video recording on basic life support skill in nursing students.BMC medical education · 2023Trial
- Comparing chest compression quality in 1-min vs. 2-min rescuer rotations with and without audiovisual feedback guidance during full adult advance life support simulated scenarios: a randomized simulation study.Resuscitation plus · 2026Article
- Performance Indicators in Emergency Medical Services: A Scoping Review of Dashboard Applications in the Context of Crisis Management.Archives of academic emergency medicine · 2026Review
- The Role of Different Feedback Devices in the Survival of Patients in Cardiac Arrest: Systematic Review with Meta-Analysis.Journal of clinical medicine · 2024Review
- Real-time feedback for CPR quality - A scoping review.Resuscitation plus · 2024Article
- Do cardiopulmonary resuscitation real-time audiovisual feedback devices improve patient outcomes? A systematic review and meta-analysis.World journal of cardiology · 2023Article
- Association of Real-Time Feedback and Cardiopulmonary-Resuscitation Quality Delivered by Ambulance Personnel for Out-of-Hospital Cardiac Arrest.Journal of the American Heart Association · 2023Article
- The effect of audiovisual feedback of monitor/defibrillators on percentage of appropriate compression depth and rate during cardiopulmonary resuscitation.BMC anesthesiology · 2023Article
- Impact of the Over-the-Head Position with a Supraglottic Airway Device on Chest Compression Depth and Rate: A Post Hoc Analysis of a Randomized Controlled Trial.Healthcare (Basel, Switzerland) · 2022Article
- Effect of Early Supraglottic Airway Device Insertion on Chest Compression Fraction during Simulated Out-of-Hospital Cardiac Arrest: Randomised Controlled Trial.Journal of clinical medicine · 2021Article
- Pulse rate as an alternative, real-time feedback indicator for chest compression rate: a porcine model of cardiac arrest.Journal of clinical monitoring and computing · 2021Article
- Article
- Effect of real-time and post-event feedback in out-of-hospital cardiac arrest attended by EMS - A systematic review and meta-analysis.Resuscitation plus · 2021Review
- Importance of Immediate Electronic-Based Feedback to Enhance Feedback for First-Time CPR Trainees.International journal of environmental research and public health · 2021Article
- Differences between manual CPR and corpuls cpr in regard to quality and outcome: study protocol of the comparing observational multi-center prospective registry study on resuscitation (COMPRESS).Scandinavian journal of trauma, resuscitation and emergency medicine · 2021Observational
- Development and Usability of a Novel Interactive Tablet App (PediAppRREST) to Support the Management of Pediatric Cardiac Arrest: Pilot High-Fidelity Simulation-Based Study.JMIR mHealth and uHealth · 2020Article
- Correction: Real-time feedback improves chest compression quality in out-of-hospital cardiac arrest: A prospective cohort study.PloS one · 2020Article
Corrections and comments
- Erratum issued
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCurrent guidelines underline the importance of high-quality chest compression during cardiopulmonary resuscitation (CPR), to improve outcomes. Contrary to this many studies show that chest compression is often carried out poorly in clinical practice, and long interruptions in compression are observed. This prospective cohort study aimed to analyse whether chest compression quality changes when a real-time feedback system is used to provide simultaneous audiovisual feedback on chest compression quality. For this purpose, pauses in compression, compression frequency and compression depth were compared.
methodsThe study included 292 out-of-hospital cardiac arrests in three consecutive study groups: first group, conventional resuscitation (no-sensor CPR); second group, using a feedback sensor to collect compression depth data without real-time feedback (sensor-only CPR); and third group, with real-time feedback on compression quality (sensor-feedback CPR). Pauses and frequency were analysed using compression artefacts on electrocardiography, and compression depth was measured using the feedback sensor. With this data, various parameters were determined in order to be able to compare the chest compression quality between the three consecutive groups.
resultsThe compression fraction increased with sensor-only CPR (group 2) in comparison with no-sensor CPR (group 1) (80.1% vs. 87.49%; P < 0.001), but there were no further differences belonging compression fraction after activation of sensor-feedback CPR (group 3) (P = 1.00). Compression frequency declined over the three study groups, reaching the guideline recommendations (127.81 comp/min vs. 122.96 comp/min, P = 0.02 vs. 119.15 comp/min, P = 0.008) after activation of sensor-feedback CPR (group 3). Mean compression depth only changed minimally with sensor-feedback (52.49 mm vs. 54.66 mm; P = 0.16), but the fraction of compressions with sufficient depth (at least 5 cm) and compressions within the recommended 5-6 cm increased significantly with sensor-feedback CPR (56.90% vs. 71.03%; P = 0.003 and 28.74% vs. 43.97%; P < 0.001).
conclusionsThe real-time feedback system improved chest compression quality regarding pauses in compression and compression frequency and facilitated compliance with the guideline recommendations. Compression depth did not change significantly after activation of the real-time feedback. Even the sole use of a CPR-feedback-sensor ("sensor-only CPR") improved performance regarding pauses in compression and compression frequency, a phenomenon known as the 'Hawthorne effect'. Based on this data real-time feedback systems can be expected to raise the quality level in some parts of chest compression quality.
trial registrationInternational Clinical Trials Registry Platform of the World Health Organisation and German Register of Clinical Trials (DRKS00009903), Registered 09 February 2016 (retrospectively registered).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials