Evidence map›Paper›PMID 32089654›Full record

ArticleJournal of interventional cardiology2019

Multicenter Assessment of Radiation Exposure during Pediatric Cardiac Catheterizations Using a Novel Imaging System.

Luke J Lamers, Brian H Morray, Alan Nugent, Michael Speidel, Petch Suntharos, Lourdes Prieto

Abstract readMulticenter Study
In one paragraph

Article in Journal of interventional cardiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Luke J LamersDepartment of Pediatrics, Cardiology Division, University of Wisconsin School of Medicine and Public Health, Madison, WI 53792, USA.ORCID https://orcid.org/0000-0001-9736-3569
Brian H MorrayDepartment of Pediatrics, Cardiology Division, University of Washington School of Medicine, Seattle, WA 98195, USA.
Alan NugentDepartment of Pediatrics, Cardiology Division, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA.
Michael SpeidelDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, WI 53705, USA.
Petch SuntharosDepartment of Pediatrics, Cardiology Division, The Cleveland Clinic, Cleveland, OH 44195, USA.
Lourdes PrietoDepartment of Pediatrics, Cardiology Division, The Cleveland Clinic, Cleveland, OH 44195, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo quantify radiation exposure during pediatric cardiac catheterizations performed by multiple operators on a new imaging platform, the Artis Q.zen (Siemens Healthcare, Forchheim, Germany), and to compare these data to contemporary benchmark values.

backgroundThe Artis Q.zen has been shown to achieve significant radiation reduction during select types of pediatric cardiac catheterizations in small single-center studies. No large multicenter study exists quantifying patient dose exposure for a broad spectrum of procedures.

methodsRetrospective collection of Air Kerma (AK) and dose area product (DAP) for all pediatric cardiac catheterizations performed on this new imaging platform at four institutions over a two-year time period.

resultsA total of 1,127 pediatric cardiac catheterizations were analyzed. Compared to dose data from earlier generation Artis Zee imaging systems, this study demonstrates 70-80% dose reduction (AK and DAP) for similar patient and procedure types. Compared to contemporary benchmark data for common interventional procedures, this study demonstrates an average percent reduction in AK and DAP from the lowest dose saving per intervention of 39% for AK and 27% for DAP for transcatheter pulmonary valve implantation up to 77% reduction in AK and 70% reduction in DAP for atrial septal defect closure.

conclusionUse of next-generation imaging platforms for pediatric cardiac catheterizations can substantially decrease patient radiation exposure. This multicenter study defines new low-dose radiation measures achievable on a novel imaging system.

Indexed as

Cardiac CatheterizationRadiation ExposureRadiography, InterventionalAdolescentChildChild, PreschoolFemaleFluoroscopyHeart DiseasesHumansInfantInfant, NewbornMaleRadiation DosageRetrospective StudiesRisk Assessment

Identifiers

PMID32089654
PMCPMC7012227

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked