Evidence map›Paper›PMID 32086764›Full record

ArticleMedical & biological engineering & computing2020

Detecting self-paced walking intention based on fNIRS technology for the development of BCI.

Chunguang Li, Jiacheng Xu, Yufei Zhu, Shaolong Kuang, Wei Qu, Lining Sun

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Review
  3. Deep Learning Based Walking Tasks Classification in Older Adults Using fNIRS.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2023
    Article
  4. Article
  5. Review
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Chunguang LiKey Laboratory of Robotics and System of Jiangsu Province School of Mechanical and Electric Engineering, Soochow University, Suzhou, China.
Jiacheng XuKey Laboratory of Robotics and System of Jiangsu Province School of Mechanical and Electric Engineering, Soochow University, Suzhou, China.
Yufei ZhuKey Laboratory of Robotics and System of Jiangsu Province School of Mechanical and Electric Engineering, Soochow University, Suzhou, China. yfzhu1997@stu.suda.edu.cn.ORCID http://orcid.org/0000-0002-3346-8203
Shaolong KuangKey Laboratory of Robotics and System of Jiangsu Province School of Mechanical and Electric Engineering, Soochow University, Suzhou, China. slkuang@suda.edu.cn.
Wei QuKey Laboratory of Robotics and System of Jiangsu Province School of Mechanical and Electric Engineering, Soochow University, Suzhou, China.
Lining SunKey Laboratory of Robotics and System of Jiangsu Province School of Mechanical and Electric Engineering, Soochow University, Suzhou, China.

Funding

National Natural Science Foundation of China 61673286National Natural Science Foundation of China U1713218Postdoctoral Science Foundation of Jiangsu Province 2017T100397
6 · The paper itself

Abstract

Since more and more elderly people suffer from lower extremity movement problems, it is of great social significance to assist persons with motor dysfunction to walk independently again and reduce the burden on caregivers. The self-paced walking intention, which could increase the ability of self-control on the start and stop of motion, was studied by applying brain-computer interface (BCI) technology, a novel research field. The cerebral hemoglobin signal, which was obtained from 30 subjects by applying functional near-infrared spectroscopy (fNIRS) technology, was processed to detect self-paced walking intention in this paper. Teager-Kaiser energy was extracted at each sampling point for five sub-bands (0.0095~0.021 Hz, 0.021~0.052 Hz, 0.052~0.145 Hz, 0.145~0.6 Hz, and 0.6~2.0 Hz). Gradient boosting decision tree (GBDT) was then utilized to establish the detecting model in real-time. The proposed method had a good performance to detect the walking intention and passed the pseudo-online test with a true positive rate of 100% (80/80), a false positive rate of 2.91% (4822/165171), and a detection latency of 0.39 ± 1.06 s. GBDT method had an area under the curve value of 0.944 and was 0.125 (p < 0.001) higher than linear discriminant analysis (LDA). The results reflected that it is feasible to decode self-paced walking intention by applying fNIRS technology. This study lays a foundation for applying fNIRS-based BCI technology to control walking assistive devices practically. Graphical abstract Graphical representation of the detecting process for pseudo-online test. The lower figure is a partial enlargement of the upper figure. In the lower figure, the blue line represents the probability of walking predicted by GBDT without smoothing and the orange-red line represents the smoothed probability. The dark-red ellipse shows the effect of the smoothing-threshold method.

Indexed as

Brain-Computer InterfacesSignal Processing, Computer-AssistedDecision TreesFemaleFrontal LobeHemoglobinsHumansMachine LearningMaleSpectroscopy, Near-InfraredWalkingHemoglobinsBrain–computer interfaceFunctional near-infrared spectroscopyGradient boosting decision treeSelf-paced walking intention

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.