ArticleTurk gogus kalp damar cerrahisi dergisi2018
The effect of transcatheter aortic valve implantation on Tp-e interval, Tp-e/QT and Tp-e/QTc ratios, and Tp-e dispersion in patients with severe aortic stenosis.
Article in Turk gogus kalp damar cerrahisi dergisi, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Tpeak-Tend ECG Marker in Obesity and Cardiovascular Diseases: A Comprehensive Review.Scientifica · 2024Review
- The relationship between myocardial bridge and frontal QRS-T angle.Journal of arrhythmia · 2022Article
- Effect of noise on the electrocardiographic parameters.International archives of occupational and environmental health · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIn this study, we aimed to investigate the effect of transcatheter aortic valve implantation using two types of bioprosthetic valves on novel ventricular repolarization markers including Tp-e, Tp-e/QT and Tpe/QTc ratios, and Tp-ed.
methodsA total of 61 patients (17 males, 44 females; mean age 78.6±6.5 years; range 55 to 89 years) who underwent transcatheter aortic valve implantation with either a Medtronic CoreValve (n=40) or an Edwards SAPIEN XT valve (n=21) were retrospectively analyzed. The electrocardiographic parameters and left ventricular mass index were calculated prior to the procedure, on postoperative Day 1, and at three months after the procedure.
resultsThe Tp-e interval, Tp-e/QT and Tp-e/QTc ratios, Tp-ed, and left ventricular mass index significantly reduced at three months of the procedure, compared to baseline values (p<0.01, for all). Similar findings were observed for QT, QTc, and QT dispersion (p<0.01, for all). These changes were independent from the types of bioprosthetic valves used. Before the procedure, the left ventricular mass index was positively correlated with the Tp-e (r=0.350, p=0.007), Tp-e/QT (r=0.314, p=0.015) and Tp-e/QTc ratios (r=0.285, p=0.029). In the multivariate analysis, Tp-e interval was found to be independently associated with the left ventricular mass index (b=0.350, p=0.007).
conclusionIn the present study, the Tp-e interval, Tp-e/QT and Tp-e/QTc ratios, Tp-ed, and left ventricular mass index significantly reduced at three months after transcatheter aortic valve implantation indicating reverse left ventricular remodeling. The effects of two types of bioprosthetic valves on ventricular repolarization markers and left ventricular mass index were similar.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.