A Pulse Signal Preprocessing Method Based on the Chauvenet Criterion.

Weiguang Ni, Jianzhuo Qi, Lijia Liu, Suyi Li

Open access · hybridAbstract read
In one paragraph

Article in Computational and mathematical methods in medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Weiguang NiCollege of Instrumentation and Electrical Engineering, Jilin University, Changchun, China.ORCID https://orcid.org/0000-0002-2479-412X
Jianzhuo QiXining No. 1 People's Hospital, Xining, China.ORCID https://orcid.org/0000-0001-6592-2020
Lijia LiuCollege of Instrumentation and Electrical Engineering, Jilin University, Changchun, China.ORCID https://orcid.org/0000-0002-8878-8968
Suyi LiCollege of Instrumentation and Electrical Engineering, Jilin University, Changchun, China.ORCID https://orcid.org/0000-0003-3599-2102
Jilin University · CNQinghai No.3 People's Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Pulse signals are widely used to evaluate the status of the human cardiovascular, respiratory, and circulatory systems. In the process of being collected, the signals are usually interfered by some factors, such as the spike noise and the poor-sensor-contact noise, which have severely affected the accuracy of the subsequent detection models. In recent years, some methods have been applied to processing the above noisy signals, such as dynamic time warping, empirical mode decomposition, autocorrelation, and cross-correlation. Effective as they are, those methods are complex and difficult to implement. It is also found that the noisy signals are tightly related to gross errors. The Chauvenet criterion, one of the gross error discrimination criterions, is highly efficient and widely applicable for being without the complex calculations like decomposition and reconstruction. Therefore, in this study, based on the Chauvenet criterion, a new pulse signal preprocessing method is proposed, in which adaptive thresholds are designed, respectively, to discriminate the abnormal signals caused by spike noise and poor-sensor-contact noise. 81 hours of pulse signals (with a sleep apnea annotated every 30 seconds and 9,720 segments in total) from the MIT-BIH Polysomnographic Database are used in the study, including 35 minutes of poor-sensor-contact noises and 25 minutes of spike noises. The proposed method was used to preprocess the pulse signals, in which 9,684 segments out of a total of 9,720 were correctly discriminated, and the accuracy of the method reached 99.63%. To quantitatively evaluate the noise removal effect, a simulation experiment is conducted to compare the Jaccard Similarity Coefficient (JSC) calculated before and after the noise removal, respectively, and the results show that the preprocessed signal obtains higher JSC, closer to the reference signal, which indicates that the proposed method can effectively improve the signal quality. In order to evaluate the method, three back-propagation (BP) sleep apnea detection models with the same network structure and parameters were established, respectively. Through comparing the recognition rate and the prediction rate of the models, higher rates were obtained by using the proposed method. To prove the efficiency, the comparison experiment between the proposed Chauvenet-based method and a Romanovsky-based method was conducted, and the execution time of the proposed method is much shorter than that of the Romanovsky method. The results suggest that the superiority in execution time of the Chauvenet-based method becomes more significant as the date size increases.

Indexed as

Heart RateSignal Processing, Computer-AssistedAdultAlgorithmsDatabases, FactualDiscriminant AnalysisElectrocardiographyFalse Positive ReactionsHumansMaleMedical InformaticsMiddle AgedPolysomnographyReproducibility of ResultsSignal-To-Noise RatioSleep Apnea Syndromes

Identifiers

PMID32082408
PMCPMC7012223
OpenAlexW2997941810

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.