Evidence map›Paper›PMID 32078702›Full record

ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2021

Optimal plate position in minimally invasive plate osteosynthesis for mid-shaft clavicle fractures: simulation using 3D-printed models of actual clinical cases.

Hyun Chul Shon, Jin-Young Bang, Yongkoo Lee, Kyoung Hwan Koh, Ji Wan Kim

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 1 country.

Hyun Chul ShonDepartment of Orthopedic Surgery, Chungbuk National University Hospital, College of Medicine, Chungbuk National University, Cheongju, South Korea.
Jin-Young BangDepartment of Orthopedic Surgery, Haeundae Paik Hospital, Inje University College of Medicine, Busan, South Korea.
Yongkoo LeeKorea Institute of Machinery and Materials, Daegu, Republic of Korea.
Kyoung Hwan KohDepartment of Orthopedic Surgery, Asan Medical Center, College of Medicine, University of Ulsan, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea.
Ji Wan KimDepartment of Orthopedic Surgery, Asan Medical Center, College of Medicine, University of Ulsan, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea. bakpaker@hanmail.net.ORCID http://orcid.org/0000-0002-3524-8706
Asan Medical Center · KRChungbuk National University Hospital · KRInje University Haeundae Paik Hospital · KRKorea Institute of Machinery & Materials · KR

Funding

Ministry of Trade, Industry and Energy 20000397
6 · The paper itself

Abstract

introductionThis study evaluated the optimal anatomical locking plate position using three-dimensional printed models of the clavicle. MATERIALS AND

methodsThree-dimensional models of the fractured clavicle were reproduced from seventeen patients who underwent minimally invasive plate osteosynthesis (MIPO) procedures. The fracture location-the percentage of the distal fragment length compared to the entire clavicle-ranged from 30-44%. We evaluated four commercially available plate systems for position and fitting with the bone. After reducing the fracture on each three-dimensional model, we determined the optimal plate and its position.

resultsThe anatomical plate fitted well when positioned in the middle of the clavicle for a fracture location ranging from 40 to 60%. When the fracture location was 30-40%, the anatomical plate fit well onto the bone model only in 36% of clavicles; otherwise, the reversed position of the anatomical plate or the lateral plate fit well. The anatomical plate was found to be unsuitable when the fracture location was less than 30%; in this case, the lateral plate was the best fit.

conclusionFitting the anatomical plate in MIPO for clavicle fractures depends on the fracture location. This can help surgeons determine the optimal plate for clavicle MIPO.

Indexed as

ClavicleFractures, BoneBone PlatesFracture Fixation, InternalHumansMinimally Invasive Surgical ProceduresPrinting, Three-DimensionalTreatment Outcome3D printingClavicleClavicle midshaft fractureMIPOPlateSimulation

Identifiers

PMID32078702
OpenAlexW3007220251

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.