Improvement of performance of minimum variance beamformer by introducing cross covariance estimate.

Hideyuki Hasegawa, Ryo Nagaoka

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of medical ultrasonics (2001), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.3field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Hideyuki HasegawaFaculty of Engineering, Academic Assembly, University of Toyama, 3190 Gofuku, Toyama, 930-8555, Japan. hasegawa@eng.u-toyama.ac.jp.ORCID http://orcid.org/0000-0003-0709-7821
Ryo NagaokaGraduate School of Science and Engineering for Research, University of Toyama, 3190 Gofuku, Toyama, 930-8555, Japan.
University of Toyama · JP

Funding

Japan Society for the Promotion of Science 19K22891Japan Society for the Promotion of Science JP17H03276
6 · The paper itself

Abstract

purposeThe delay-and-sum beamformer is widely used in clinical ultrasound systems to obtain ultrasonic images. To improve image quality, the minimum variance (MV) beamformer was introduced in medical ultrasound imaging. The MV beamformer determines beamformer weights from ultrasonic echo signals received by individual transducer elements in an ultrasonic probe. In the present study, the MV beamformer was investigated to improve its performance.

methodsIn MV beamforming, a covariance matrix of echo signals received by individual elements needs to be estimated to obtain adaptive beamformer weights. To obtain a stable estimate, a total receiving aperture is divided into subarrays, and a covariance matrix is obtained using echo signals from each subarray to average covariance matrices from all subarrays. This procedure is called "subarray averaging." In the present study, a new method for estimation of the covariance matrix was proposed. In the proposed method, a covariance matrix, namely, a cross covariance matrix, is obtained using echo signals from different subarrays. Multiple covariance matrices are obtained from all different pairs of subarrays and averaged.

resultsIn the present study, the performance of the proposed method was evaluated by basic experiments on a phantom. Lateral spatial resolutions obtained by MV beamforming with conventional subarray averaging and the proposed method were similar. However, contrast obtained by MV beamforming with the proposed method was - 0.56 dB, which was significantly better than the - 5.06 dB obtained by MV beamforming with conventional subarray averaging.

conclusionImage contrast in MV beamforming could be improved significantly by estimating "cross" covariance matrices.

Indexed as

Signal Processing, Computer-AssistedAlgorithmsImage Processing, Computer-AssistedPhantoms, ImagingReproducibility of ResultsTransducersUltrasonographyCovariance matrixImage qualityMinimum variance beamformingSubarray averaging

Identifiers

PMID32078070
OpenAlexW3007349412

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.