Evidence map›Paper›PMID 32077260›Full record

ArticleOrthopaedic surgery2020

Comparison of Different Insertion Techniques for Lumbosacral Fixation Improvement: A Finite Element Study.

Da-Peng Han, Jia-Yin Wang

Open access · goldAbstract readComparative Study
In one paragraph

Article in Orthopaedic surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Da-Peng HanDepartment of Spinal Surgery, Shandong Province Hospital Affiliated to Shandong University, Jinan, China.ORCID https://orcid.org/0000-0001-7138-4652
Jia-Yin WangDepartment of Spinal surgery, Armed Police Hospital of Shandong Province, Jinan, China.
Shandong Police College · CNShandong University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveWe create a new S1 cortical screw trajectory technique using 3D reconstruction and the finite element (FE) method to provide a more reliable theoretical basis for clinical practices and to advance internal fixation technology for treatment of lumbosacral degenerative diseases.

methodsThis retrospective study included patients (aged from 40 to 70 years) who needed intervertebral fusion surgery between August 2016 and August 2017. Data of patients with lumbosacral lesions was scanned and measured by 64-row spiral CT, and were then transmitted to the GE-AW4.3 post-processing system for 3D reconstruction. The trajectories of the three different screws were simulated by FE software and processed by mimics software to simulate the screw path: traditional PS fixation (Model A); traditional cortical screw (Model B); and new cortical screw (Model C). The CT value of the bone around the screw canal was recorded. Biomechanical effects of the three screws were analyzed and compared.

resultsThe displacement of flexion and extension, the vertebral body stress of right torsion, and the cage stress of flexion showed no significant differences among the three models (P > 0.05). The results demonstrated that cortical screws exceeded pedicle screws in stability and pullout force. Models B and C showed higher vertebral displacement in left bending (0.41 and 0.31 mm) and right bending (0.58 and 0.40 mm), lower vertebral body stress on extension (48.37 and 38.92 MPa), left bending (0.76 and 0.74 mm) and right bending (0.50 and 0.53 mm), and higher cage stress on left bending (162.19 and 160.63 MPa), right bending (150.02 and 150.05 MPa), left torsion (158.45 and 146.27 MPa) and right torsion (167.33 and 171.15 MPa) (all P < 0.05) compared to model A. Compared to Model B, Model C had higher displacement of left and right torsion, lower pressure in extension and flexion, and lower stress on cages in extension (P < 0.05).

conclusionThe new cortical screw insertion method has similar effects to traditional cortical screw fixation. However, it demonstrated advantages in promoting lumbosacral interbody fusion, which protects vessels and nerves.

Indexed as

Bone ScrewsAdultAgedBiomechanical PhenomenaFinite Element AnalysisFracture Fixation, InternalHumansImaging, Three-DimensionalLumbar VertebraeMiddle AgedRetrospective StudiesSacrumSpinal FusionCortical bone trajectoryFinite element methodInsertion techniqueLumbosacral fixationPedicle screw

Identifiers

PMID32077260
PMCPMC7031541
OpenAlexW3008134479

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.