Evidence map›Paper›PMID 32077011›Full record

ArticleMedical & biological engineering & computing2020

A novel noncontact detection method of surgeon's operation for a master-slave endovascular surgery robot.

Yan Zhao, Huiming Xing, Shuxiang Guo, Yuxin Wang, Jinxin Cui, Youchun Ma, Yu Liu, Xinke Liu, Junqiang Feng, Youxiang Li

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
3.6field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 46 citations in OpenAlex.

  1. Sensors for Robots.Sensors (Basel, Switzerland) · 2024
    Article
  2. Article
  3. Remote vascular interventional surgery robotics: a literature review.Quantitative imaging in medicine and surgery · 2022
    Review
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 3 countries.

Yan ZhaoSchool of Mechanical Engineering, Hebei University of Technology, No.5340 Rd. Xiping, Beichen District, Tianjin, 300401, China.ORCID http://orcid.org/0000-0003-2248-5507
Huiming XingKey Laboratory of Convergence Biomedical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, No.5, Zhongguancun South Street, Haidian District, Beijing, 100081, China.
Shuxiang GuoKey Laboratory of Convergence Biomedical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, No.5, Zhongguancun South Street, Haidian District, Beijing, 100081, China. guoshuxiang@bit.edu.cn.
Yuxin WangKey Laboratory of Convergence Biomedical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, No.5, Zhongguancun South Street, Haidian District, Beijing, 100081, China.
Jinxin CuiKey Laboratory of Convergence Biomedical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, No.5, Zhongguancun South Street, Haidian District, Beijing, 100081, China.
Youchun MaKey Laboratory of Convergence Biomedical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, No.5, Zhongguancun South Street, Haidian District, Beijing, 100081, China.
Yu LiuKey Laboratory of Convergence Biomedical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, No.5, Zhongguancun South Street, Haidian District, Beijing, 100081, China.
Xinke LiuDepartment of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, 100050, China.
Junqiang FengDepartment of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, 100050, China.
Youxiang LiDepartment of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, 100050, China.
Beijing Institute of Technology · CNCapital Medical University · CNUniversity of California, San Francisco · US

Funding

National High-tech R&D Program (863 Program) of China No.2015AA043202National Key Research and Development Program of China 2017YFB1304401
6 · The paper itself

Abstract

Master-slave endovascular interventional surgery (EIS) robots have brought revolutionary advantages to traditional EIS, such as avoiding X-ray radiation to the surgeon and improving surgical precision and safety. However, the master controllers of most of the current EIS robots always lead to bad human-machine interaction, because of the difference in nature between the rigid operating handle and the flexible medical catheter used in EIS. In this paper, a noncontact detection method is proposed, and a novel master controller is developed to realize real-time detection of surgeon's operation without interference to the surgeon. A medical catheter is used as the operating handle. It is enabled by using FAST corner detection algorithm and optical flow algorithm to track the corner points of the continuous markers on a designed sensing pipe. A mathematical model is established to calculate the axial and rotational motion of the sensing pipe according to the moving distance of the corner points in image coordinates. A master-slave EIS robot system is constructed by integrating the proposed master controller and a developed slave robot. Surgical task performance evaluation in an endovascular evaluator (EVE) is conducted, and the results indicate that the proposed detection method breaks through the axial measuring range limitation of the previous marker-based detection method. In addition, the rotational detection error is reduced by 92.5% compared with the previous laser-based detection method. The results also demonstrate the capability and efficiency of the proposed master controller to control the slave robot for surgical task implementation. Graphical abstract A novel master controller is developed to realize real-time noncontact detection of surgeon's operation without interference to the surgeon. The master controller is used to remotely control the slave robot to implement certain surgical tasks.

Indexed as

AlgorithmsEndovascular ProceduresEquipment DesignHumansOperative TimeRobotic Surgical ProceduresSurgeonsVascular Access DevicesContinuous noncontact detectionEndovascular surgery robotMaster controllerSurgeon’s operation detection

Identifiers

PMID32077011
OpenAlexW3007088326

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.