Trial reportHernia : the journal of hernias and abdominal wall surgery2020
Does the use of monopolar energy as the preferred mode of dissection effectively reduce seroma formation in laparoscopic total extra peritoneal hernioplasty? A prospective double-blinded randomized control trial.
Trial report in Hernia : the journal of hernias and abdominal wall surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04960267 (Use of Pre-peritoneal Drainage in rTAPP - a Comparative Study With Laparoscopic TEP), which is not on this map. Cited by 12 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Use of Pre-peritoneal Drainage in rTAPP - a Comparative Study With Laparoscopic TEP
Who cites it
12 citing papers in PubMed, 1 synthesis or guideline pooled it, 19 citations in OpenAlex.
- Differences in the rates of seroma complications between hernial sac transection and reduction after laparoscopic inguinal hernia repair: systematic review and meta-analysis.Scientific reports · 2025Pooled it
- Effects of intraoperative fixation of residual hernia sac on postoperative seroma in laparoscopic transabdominal preperitoneal inguinal hernia repair: a prospective randomized controlled trial.Updates in surgery · 2023Trial
- Review
- Comparison of advanced bipolarAnnals of surgical treatment and research · 2025Article
- Short-term outcomes of puncturing forceps-assisted laparoscopic totally extraperitoneal hernioplasty for indirect inguinal hernia: a prospective randomized study.Updates in surgery · 2025Article
- Comparison of anatomical polyester mesh without fixation and conventional flat mesh with fixation in laparoscopic total extraperitoneal repair for inguinal hernia.Hernia : the journal of hernias and abdominal wall surgery · 2025Article
- Subcutaneous fat thickness predicts postoperative seroma following laparoscopic total extra-peritoneal hernioplasty.Hernia : the journal of hernias and abdominal wall surgery · 2024Article
- Laparoscopic total extraperitoneal (TEP) inguinal hernia repair with preperitoneal closed-suction drainage reduced postoperative complications.BMC surgery · 2023Article
- Internal Ring Defect Closure Technique in Laparoscopic Mesh Hernioplasty for Indirect Inguinal Hernia.Frontiers in surgery · 2022Article
- Seroma after TEP, preventable or not?Hernia : the journal of hernias and abdominal wall surgery · 2021Article
- Seroma after TEP, preventable or not? Author's reply.Hernia : the journal of hernias and abdominal wall surgery · 2021Article
- A randomised controlled study on the effects of hernial sac stump fenestration on ultrasound seroma prevention in laparoscopic Type III inguinal hernia repair.Journal of minimal access surgeryArticle
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
8 authors at 3 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionSeroma is a commonly encountered sequela after hernia repair. Tremendous effort has been spent to investigate the effective way to prevent this "complication" including the modification of surgical technique, use of per-peritoneal drainage, etc. There were debates about the use of monopolar diathermy versus blunt dissection in laparoscopic TEP in the prevention of seroma formation. This randomized study aims to compare the effects of using 2 techniques in laparoscopic TEP on pre-peritoneal drain output and seroma formation.
methodFrom 1.9.2018 to 30.9.2019, all male and female patients presented with the first occurrence, unilateral inguinal hernia anticipated for laparoscopic TEP were enrolled into the study after informed consent. Patients were randomized into "monopolar dissection preferred" (MDP) group and "blunt dissection-preferred" (BDP) group just before commencing of operation after general anesthesia. Surgeons were instructed to use monopolar energy as main dissection method for the whole operation if possible (MDP), whereas blunt dissection is the preferred choice in BDP group, but the use of monopolar energy was allowed if needed. Total energy time was measured by a specially designed homemade device attaching to the monopolar pedals as accurate as to millisecond (ms). Pre-peritoneal drains were inserted for drainage and removed 23 h after operation. Drainage output, total operating time, energy time, clinical and ultrasonic seroma sizes at day 1, day 6, 1-month post operations, recurrence are compared between 2 groups.
resultsA total of 103 patients where included. There was no significant difference in age, gender, co-morbidities, side of hernia, mean defect size, operating time, fixation adjuncts, or postoperative stay. The drain volume in BDP group is 71.13 ± 31.42 mL while it in MDP group is 56.36 ± 21.46 mL. The MDP group had significantly fewer drain output at 23 h post operation (p = 0.007) and lower seroma incidence on days 6 (p = 0.036). Overall incidence of seroma formation was 12% on postoperative day 1, 11% on postoperative day 7. No statistically differences in postoperative pain score or complications were observed at the first week, 1- and 3-months' post operation. There was no correlation with energy time to the drain output. No recurrence was found in subsequent follow-up.
conclusionPre-peritoneal drainage is clinically safe in laparoscopic totally extra-peritoneal hernioplasty and can effectively reduce the size and incidence of seroma. The seroma formation can be further reduced by appropriate use of monopolar energy as preferred dissection approach in lap TEP. Due to limitation in measuring the actual energy time, the result should be further validated by randomized multi-centers trial on its potential benefit in hernia repair by a more accurate measuring device on energy used.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.