Evidence map›Paper›PMID 32068347›Full record

ArticleJournal of applied clinical medical physics2020

Dynamic gating window technique for the reduction of dosimetric error in respiratory-gated spot-scanning particle therapy: An initial phantom study using patient tumor trajectory data.

Naoki Miyamoto, Kouhei Yokokawa, Seishin Takao, Taeko Matsuura, Sodai Tanaka, Shinichi Shimizu, Hiroki Shirato, Kikuo Umegaki

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Naoki MiyamotoDivision of Quantum Science and Engineering, Faculty of Engineering, Hokkaido University, Sapporo, Japan.
Kouhei YokokawaDivision of Quantum Science and Engineering, Faculty of Engineering, Hokkaido University, Sapporo, Japan.
Seishin TakaoGlobal Station for Quantum Medical Science and Engineering, Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University, Sapporo, Japan.
Taeko MatsuuraDivision of Quantum Science and Engineering, Faculty of Engineering, Hokkaido University, Sapporo, Japan.
Sodai TanakaDivision of Quantum Science and Engineering, Faculty of Engineering, Hokkaido University, Sapporo, Japan.
Shinichi ShimizuGlobal Station for Quantum Medical Science and Engineering, Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University, Sapporo, Japan.
Hiroki ShiratoGlobal Station for Quantum Medical Science and Engineering, Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University, Sapporo, Japan.
Kikuo UmegakiDivision of Quantum Science and Engineering, Faculty of Engineering, Hokkaido University, Sapporo, Japan.

Funding

JSPS KAKENHI 17H04115
6 · The paper itself

Abstract

Spot-scanning particle therapy possesses advantages, such as high conformity to the target and efficient energy utilization compared with those of the passive scattering irradiation technique. However, this irradiation technique is sensitive to target motion. In the current clinical situation, some motion management techniques, such as respiratory-gated irradiation, which uses an external or internal surrogate, have been clinically applied. In surrogate-based gating, the size of the gating window is fixed during the treatment in the current treatment system. In this study, we propose a dynamic gating window technique, which optimizes the size of gating window for each spot by considering a possible dosimetric error. The effectiveness of the dynamic gating window technique was evaluated by simulating irradiation using a moving target in a water phantom. In dosimetric characteristics comparison, the dynamic gating window technique exhibited better performance in all evaluation volumes with different effective depths compared with that of the fixed gate approach. The variation of dosimetric characteristics according to the target depth was small in dynamic gate compared to fixed gate. These results suggest that the dynamic gating window technique can maintain an acceptable dose distribution regardless of the target depth. The overall gating efficiency of the dynamic gate was approximately equal or greater than that of the fixed gating window. In dynamic gate, as the target depth becomes shallower, the gating efficiency will be reduced, although dosimetric characteristics will be maintained regardless of the target depth. The results of this study suggest that the proposed gating technique may potentially improve the dose distribution. However, additional evaluations should be undertaken in the future to determine clinical applicability by assuming the specifications of the treatment system and clinical situation.

Indexed as

Phantoms, ImagingAlgorithmsComputer SimulationHumansLungLung NeoplasmsRadiation DosageRadiometryRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-Assistedgated irradiationgating windowproton therapyrespiratory motionspot-scanning

Identifiers

PMID32068347
PMCPMC7170289

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.