Evidence map›Paper›PMID 32065696›Full record

ArticleNeuromodulation : journal of the International Neuromodulation Society2021

Cost-Effectiveness Model Shows Superiority of Wireless Spinal Cord Stimulation Implantation Without a Separate Trial.

Richard B North, Harish S Parihar, Shawn D Spencer, Arthur F Spalding, Jane Shipley

Open access · bronzeAbstract read
In one paragraph

Article in Neuromodulation : journal of the International Neuromodulation Society, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.5field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 12 citations in OpenAlex.

  1. Spinal Cord Stimulation for Painful Diabetic Neuropathy.Journal of diabetes science and technology · 2024
    Review
  2. Article
  3. Review
  4. Advances in Neuromodulation for Chronic Pain.Journal of clinical medicine · 2022
    Article
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Richard B NorthThe Neuromodulation Foundation, Inc., Baltimore, MD, USA.ORCID https://orcid.org/0000-0002-7360-3641
Harish S PariharPhiladelphia College of Osteopathic Medicine (PCOM) Georgia, Suwanee, GA, USA.
Shawn D SpencerPhiladelphia College of Osteopathic Medicine (PCOM) Georgia, Suwanee, GA, USA.
Arthur F SpaldingTAMM Net, Inc., Atlanta, GA, USA.
Jane ShipleyThe Neuromodulation Foundation, Inc., Baltimore, MD, USA.ORCID https://orcid.org/0000-0002-3319-7546
International Neuromodulation Society · USPhiladelphia College of Osteopathic Medicine · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveWe evaluated the cost-effectiveness of wireless spinal cord stimulation (Wireless SCS) with single stage "direct to permanent" implantation vs. screening with temporary electrodes and an external pulse generator followed by implantation of a system for long-term use (IPG SCS). MATERIALS AND

methodsWe created a cost model that takes a 2019 United States (U.S.) payer perspective and is based on IPG SCS cost models for subjects with chronic back and/or leg pain. Our six-month decision tree includes the screening trial period (success ≥50% relief) and leads to various levels of pain relief with or without complications for IPG SCS and Wireless SCS and without complications for conventional medical management (CMM). Every three months in the follow-on 15-year Markov model (with costs and quality-adjusted life years discounted 3.5% annually), subjects remain stable or transition to deteriorated health or death. Subjects who fail SCS receive CMM. After 60 Markov cycles, a 100,000-sample simulation reveals the impact of maximum willingness-to-pay (WTP) from $10,000 to $100,000 per quality-adjusted life year on net monetary benefit (NMB). Sensitivity analyses considered the impact of the Wireless SCS screening success rate, Wireless SCS device cost, and IPG SCS device longevity.

resultsCompared with IPG SCS, Wireless SCS offers higher clinical effectiveness at a lower cost and a higher NMB for our WTP thresholds and is, thus, dominant. Wireless SCS is also cost-effective compared with CMM. Results remain robust with 1) Wireless SCS screening success rates as low as 85% (dominant), 2) the cost of the Wireless SCS devices as high as $55,000 (cost-effective), and 3) IPG SCS devices lasting 12 years (dominant).

conclusionsIn this model, compared with IPG SCS or with CMM, Wireless SCS is a superior strategy.

Indexed as

Spinal Cord StimulationCost-Benefit AnalysisHumansPainPain ManagementQuality-Adjusted Life YearsSpinal CordCost-effectivenessmodeling studySCS health economicsspinal cord stimulationwireless SCS

Identifiers

PMID32065696
PMCPMC8246551
OpenAlexW3007068997

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.