Evidence map›Paper›PMID 32064570›Full record

ArticleAnalytical and bioanalytical chemistry2020

A microfluidic electrochemical flow cell capable of rapid on-chip dilution for fast-scan cyclic voltammetry electrode calibration.

Lauren M Delong, Yuxin Li, Gary N Lim, Salmika G Wairegi, Ashley E Ross

Abstract read
PubMed Publisher
In one paragraph

Article in Analytical and bioanalytical chemistry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Lauren M DelongUniversity of Cincinnati - Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH, 45221-0172, USA.
Yuxin Li *University of Cincinnati - Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH, 45221-0172, USA.
Gary N Lim *University of Cincinnati - Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH, 45221-0172, USA.
Salmika G WairegiUniversity of Cincinnati - Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH, 45221-0172, USA.
Ashley E RossUniversity of Cincinnati - Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH, 45221-0172, USA. Ashley.ross@uc.edu.ORCID http://orcid.org/0000-0003-2456-3636
University of Cincinnati · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Here, we developed a microfluidic electrochemical flow cell for fast-scan cyclic voltammetry which is capable of rapid on-chip dilution for efficient and cost-effective electrode calibration. Fast-scan cyclic voltammetry (FSCV) at carbon-fiber microelectrodes is a robust electroanalytical technique used to measure subsecond changes in neurotransmitter concentration over time. Traditional methods of electrode calibration for FSCV require several milliliters of a standard. Additionally, generating calibration curves can be time-consuming because separate solutions must be prepared for each concentration. Microfluidic electrochemical flow cells have been developed in the past; however, they often require incorporating the electrode in the device, making it difficult to remove for testing in biological tissues. Likewise, current microfluidic electrochemical flow cells are not capable of rapid on-chip dilution to eliminate the requirement of making multiple solutions. We designed a T-channel device, with microchannel dimensions of 100 μm × 50 μm, that delivered a standard to a 2-mm-diameter open electrode sampling well. A waste channel with the same dimensions was designed perpendicular to the well to flush and remove the standard. The dimensions of the T-microchannels and flow rates were chosen to facilitate complete mixing in the delivery channel prior to reaching the electrode. The degree of mixing was computationally modeled using COMSOL and was quantitatively assessed in the device using both colored dyes and electrochemical detection. On-chip electrode calibration for dopamine with FSCV was not significantly different than the traditional calibration method demonstrating its utility for FSCV calibration. Overall, this device improves the efficiency and ease of electrode calibration. Graphical abstract.

Indexed as

Carbon-fiber microelectrodeDopamineElectrochemistryFlow cellMicrofluidicsT-channel

Identifiers

PMID32064570
OpenAlexW3008906571

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.