Evidence map›Paper›PMID 32056391›Full record

ArticleJournal of medical radiation sciences2020

An investigation into the effect of changing the computed tomography slice reconstruction interval on the spatial replication accuracy of three-dimensional printed anatomical models constructed by fused deposition modelling.

Ben Searle, Deborah Starkey

Open access · goldAbstract read
In one paragraph

Article in Journal of medical radiation sciences, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
0.8field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Ben SearleRedcliffe Hospital, Redcliffe, QLD, Australia.ORCID https://orcid.org/0000-0003-1227-0721
Deborah StarkeySchool of Clinical Sciences, Faculty of Health, Queensland University of Technology, Brisbane, QLD, Australia.ORCID https://orcid.org/0000-0002-8353-4977
Queensland University of Technology · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThree-dimensional (3D) printed models can be constructed utilising computed tomography (CT) data. This project aimed to determine the effect of changing the slice reconstruction interval (SRI) on the spatial replication accuracy of 3D-printed anatomical models constructed by fused deposition modelling (FDM).

methodsThree bovine vertebrae and an imaging phantom were imaged using a CT scanner. The Queensland State Government's Animal Care and Protection Act 2001 did not apply as no animals were harmed to carry out scientific activity. The data were reconstructed into SRIs of 0.1, 0.3, 0.5 and 1 mm and processed by software before 3D printing. Specimens and printed models were measured with calipers to calculate mean absolute error prior to statistical analysis.

resultsMean absolute error from the original models for the 0.1, 0.3, 0.5 and 1 mm 3D-printed models was 0.592 ± 0.396 mm, 0.598 ± 0.479 mm, 0.712 ± 0.498 mm and 0.933 ± 0.457 mm, respectively. Paired t-tests (P < 0.05) indicated a statistically significant difference between all original specimens and corresponding 3D-printed models except the 0.1 mm vertebrae 2 (P = 0.061), 0.3 mm phantom 1 (P = 0.209) and 0.3 mm vertebrae 2 (P = 0.097).

conclusionThis study demonstrated that changing the SRI influences the spatial replication accuracy of 3D-printed models constructed by FDM. Matching the SRI to the primary spatial resolution limiting factor of acquisition slice width or printer capabilities optimises replication accuracy.

Indexed as

AnimalsCattleImaging, Three-DimensionalPhantoms, ImagingPrinting, Three-DimensionalReference StandardsSpineTomography, X-Ray Computed3D-printingbiofabricationcomputed tomographyfused deposition modellingslice reconstruction interval

Identifiers

PMID32056391
PMCPMC7063250
OpenAlexW3006516587

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.