Evidence map›Paper›PMID 32053865›Full record

ArticleMolecules (Basel, Switzerland)2020

Methods of Granulocyte Isolation from Human Blood and Labeling with Multimodal Superparamagnetic Iron Oxide Nanoparticles.

Fernando Alvieri, Javier B Mamani, Mariana P Nucci, Fernando A Oliveira, Igor S Filgueiras, Gabriel N A Rego, Marycel F de Barboza, Helio R da Silva, Lionel F Gamarra

Abstract read
In one paragraph

Article in Molecules (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Fernando AlvieriHospital Israelita Albert Einstein, São Paulo 05652-900, Brazil.
Javier B MamaniHospital Israelita Albert Einstein, São Paulo 05652-900, Brazil.
Mariana P NucciLIM44-Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de São Paulo,São Paulo 01246-903, Brazil.
Fernando A OliveiraHospital Israelita Albert Einstein, São Paulo 05652-900, Brazil.
Igor S FilgueirasHospital Israelita Albert Einstein, São Paulo 05652-900, Brazil.
Gabriel N A RegoHospital Israelita Albert Einstein, São Paulo 05652-900, Brazil.
Marycel F de BarbozaHospital Israelita Albert Einstein, São Paulo 05652-900, Brazil.
Helio R da SilvaHospital Israelita Albert Einstein, São Paulo 05652-900, Brazil.
Lionel F GamarraHospital Israelita Albert Einstein, São Paulo 05652-900, Brazil.

Funding

Conselho Nacional de Desenvolvimento Científico e Tecnológico 400856/2016-6Fundação de Amparo à Pesquisa do Estado de São Paulo 2016/21470-3; 2014/50983-3
6 · The paper itself

Abstract

This in vitro study aimed to find the best method of granulocyte isolation for subsequentlabeling with multimodal nanoparticles (magnetic and fluorescent properties) to enable detectionby optical and magnetic resonance imaging (MRI) techniques. The granulocytes were obtained fromvenous blood samples from 12 healthy volunteers. To achieve high purity and yield, four differentmethods of granulocyte isolation were evaluated. The isolated granulocytes were labeled withmultimodal superparamagnetic iron oxide nanoparticles (M-SPIONs) coated with dextran, and theiron load was evaluated qualitatively and quantitatively by MRI, near-infrared fluorescence (NIRF)and inductively coupled plasma mass spectrometry (ICP-MS). The best method of granulocyteisolation was Percoll with Ficoll, which showed 95.92% purity and 94% viability. After labeling withM-SPIONs, the granulocytes showed 98.0% purity with a yield of 3.5 × 106 cells/mL and more than98.6% viability. The iron-loading value in the labeled granulocytes, as obtained by MRI, was 6.40 ±0.18 pg/cell. Similar values were found with the ICP-MS and NIRF imaging techniques. Therefore,our study shows that it is possible to isolate granulocytes with high purity and yield and labelingwith M-SPIONs provides a high internalized iron load and low toxicity to cells. Therefore, these MSPION-labeled granulocytes could be a promising candidate for future use ininflammation/infection detection by optical and MRI techniques.

Indexed as

GranulocytesStaining and LabelingAnalysis of VarianceCell SeparationCell SurvivalFerric CompoundsHumansImmunophenotypingMagnetic Resonance SpectroscopyMagnetite NanoparticlesMolecular ImagingFerric Compoundsferric oxideMagnetite Nanoparticlesgranulocyte isolationICP-MSinfectioninflammationmagnetic nanoparticlemagnetic resonance imagingmolecular imagingnear-infrared fluorescenceSPION

Identifiers

PMID32053865
PMCPMC7070653

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.