Evidence map›Paper›PMID 32053281›Full record

ArticleOrthopaedic surgery2020

Computational Biomechanical Analysis of Postoperative Calcaneal Fractures with Different Placement of the Sustentaculum Screw.

Min-Fei Qiang, Ritesh Kumar Singh, Yan-Xi Chen, Kun Zhang, Xiao-Yang Jia, Song Chen, Shu-Guang Wang, Xiong Wang, Zhao-Man Shi

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
2.1field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 25 citations in OpenAlex.

  1. Percutaneous fixation of intraarticular joint-depression calcaneal fractures with different screw configurations - a biomechanical human cadaveric analysis.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2022
    Trial
  2. Article
  3. In Vitro Experimental Study of BiofiligreeBioengineering (Basel, Switzerland) · 2026
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Modeling and analysis of explicit dynamics of foot landing.Medical & biological engineering & computing · 2025
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Min-Fei QiangDepartment of Orthopaedic Surgery, Zhongshan Hospital, Fudan University, Shanghai, China.
Ritesh Kumar SinghDepartment of Orthopaedic Trauma, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China.
Yan-Xi ChenDepartment of Orthopaedic Surgery, Zhongshan Hospital, Fudan University, Shanghai, China.ORCID https://orcid.org/0000-0002-4021-6020
Kun ZhangDepartment of Orthopaedic Trauma, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China.
Xiao-Yang JiaDepartment of Orthopaedic Trauma, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China.
Song ChenDepartment of Orthopaedic Trauma, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China.
Shu-Guang WangDepartment of Orthopaedic Trauma, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China.
Xiong WangDepartment of Orthopaedic Trauma, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China.
Zhao-Man ShiDepartment of Orthopaedic Trauma, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China.
Shanghai East Hospital · CNFudan University · CN

Funding

Municipal Human Resources Development Program for Outstanding Leaders in Medical Disciplines in Shanghai 2017BR059National Natural Science Foundation of China 81672141the Municipal Human Resources Development Program for Outstanding Leaders in Medical Disciplines in Shanghai 2017BR059
6 · The paper itself

Abstract

objectiveTo evaluate the computational biomechanical analysis of intra-articular calcaneal fractures with different fixation status of the sustentaculum plate screw, when the finite element modeling of calcaneal fractures were fixed by the lateral locking plate.

methodsThe normal right foot of a male (age: 36 years; height: 174 cm; body weight: 65 kg) was scanned by the CT scanner. As the computational biomechanical study, the three-dimensional finite element model of the simplified Sanders type-II calcaneal fracture was built. Fixation with the lateral calcaneal locking plate and screws was simulated using a finite element software package according to clinical operation. According to the different placement of the sustentaculum plate screw, the models were categorized as the accurate fixation group, marginal fixation group, and non-fixation group. The loading of 650 N with the vertical axial compression was applied to simulate the standing phase with single foot. The Von Mises stress distribution, maximal displacement, and contact area of the subtalar joint were analyzed among three groups.

resultsThe pressure distribution of the subtalar joint facet was inhomogeneous. The stress concentration of the calcaneus was located at the medial zone of the posterior subtalar joint facet. The peak Von Mises stress distribution in three groups was similar at the subtalar joint facet of 4.9 MPa, 5.1 MPa, and 5.4 MPa. In the accurate fixation group, the contact area on the posterior articular facet was 277.1 mm

conclusionsThe biomechanical results, including the peak stress distribution, contact area, and maximal displacement of subtalar joint, were similar whether the screw is placed exactly within the sustentaculum tali or not, when the calcaneal fractures were fixed by the lateral locking plate. The sustentaculum plate screw had less effect on the biomechanical performance of the calcaneus.

Indexed as

Bone PlatesBone ScrewsAdultBiomechanical PhenomenaCalcaneusFinite Element AnalysisFracture Fixation, InternalFractures, BoneHumansMalePostoperative PeriodCalcaneusFinite element analysisFracture fixation, InternalIntra-articular fractures

Identifiers

PMID32053281
PMCPMC7189067
OpenAlexW3005837114

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.