ArticleDocumenta ophthalmologica. Advances in ophthalmology2020
XEN Gel Stent in the management of primary open-angle glaucoma.
Article in Documenta ophthalmologica. Advances in ophthalmology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 5 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 5 syntheses or guidelines pooled it, 32 citations in OpenAlex.
- Comparison of XEN gel stent for management of open-angle glaucoma: a systematic review and meta-analysis.PeerJ · 2026Pooled it
- Efficacy of XEN gel stent implantation combined with mitomycin C injection in the treatment of open-angle glaucoma: a meta-analysis.International ophthalmology · 2024Pooled it
- Complications and post-operative interventions in XEN45 gel stent implantation in the treatment of open angle glaucoma-a systematic review and meta-analysis.Eye (London, England) · 2023Pooled it
- The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis.BMC ophthalmology · 2022Pooled it
- The Outcomes of XEN Gel Stent Implantation: A Systematic Review and Meta-Analysis.Frontiers in medicine · 2022Pooled it
- Complications Following XEN45 Gel Stent and Glaucoma Drainage Device Implantation During Glaucoma Fellowship.Cureus · 2024Article
- Effectiveness and Safety of Xen Gel Stent in Glaucoma Surgery: A Systematic Review of the Literature.Journal of clinical medicine · 2023Review
- Intraocular Pressure and Medication Changes Associated with Xen Gel Stent: A Systematic Review of the Literature.Clinical ophthalmology (Auckland, N.Z.) · 2023Review
- Conventional glaucoma implants and the new MIGS devices: a comprehensive review of current options and future directions.Eye (London, England) · 2021Review
- Efficacy and Safety Outcomes of XEN Implantation and Gonioscopy-assisted Transluminal Trabeculotomy for the Management of Advanced Open-angle Glaucoma.Journal of current glaucoma practiceArticle
- XEN Gel Stent Failure Due to Luminal Obstruction.Journal of ophthalmic & vision researchArticle
- Two-year Outcomes of XEN Implantation with Minimal Bleb Needling.Journal of current glaucoma practiceArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo assess the efficacy and safety of the XEN Gel Stent in patients with primary open-angle glaucoma. MATERIALS AND
methodsTwenty eyes of 17 patients (6 males, 11 females) with primary open-angle glaucoma were implanted with XEN Gel Stent. The following data were ascertained in each participant at baseline and at 1, 3, 6, 9 and 12 months following implanting procedure: intraocular pressure, number of anti-glaucoma medications, retinal sensitivity (PS 24/2 w/w), pattern electroretinogram (ISCEV standard), as well as the number of complications.
resultsThe mean intraocular pressure reduction in a 1-year follow-up was 18% (21.56 vs. 17.69 mmHg, p < 0.001). The mean number of anti-glaucoma medications was reduced from 3.2 to 1.6 (p = 0.001). The PERG parameters at baseline and at 12 months postoperatively included a stable amplitude of P50 (2.55 µV vs. 2.65 µV, p = 0.024) and N95 (3.45 µV vs. 3.38 µV, p = ns) waves. The delta N95 and delta P50 amplitudes remained stable over the follow-up period (p = ns). The mean deviation (MD) of PS 24/2 was - 6.54 dB vs. - 8.43 dB, p = ns, whereas the pattern standard deviation (PSD) was 6.18 dB vs. 6.91 dB, p = ns. Transient hypotony within the first postoperative week occurred in 18 eyes (90%), whereas hyphema occurred in two eyes (10%). Needle revision of a filtration bleb was performed in five eyes (25%).
conclusionsThe XEN Gel Stent enables significant reduction in intraocular pressure with very low complication rates. It ensures a stabilization of the retinal function as established with the PERG.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.