ArticleNPJ digital medicine2020
Investigating sources of inaccuracy in wearable optical heart rate sensors.
Article in NPJ digital medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 315 papers, 9 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Study of Clinical Biomarkers in Human Health and Disease (Healthiomics)
Comparative Evaluation of the Effectiveness of Levothyroxine Replacement Therapy After Total Thyroidectomy Using Smart Wristband-Measured Nocturnal Heart Rate and Heart Rhythm Parameters Versus Thyroid Function Tests
Who cites it
315 citing papers in PubMed, 9 syntheses or guidelines pooled it.
- Use of Wearable Sensors in Angelman Syndrome: A Systematic Review.Journal of intellectual disability research : JIDR · 2026Pooled it
- The Micro-Mobility Sensing Gap: A Systematic Review of Physiological Safety Monitoring from Cycling to E-Scooters.Sensors (Basel, Switzerland) · 2026Pooled it
- A Systematic Review of Wearable Sensors in Rett Syndrome-What Physiological Markers Are Informative for Monitoring Disease States?Sensors (Basel, Switzerland) · 2025Pooled it
- A Systematic Review of Chest-Worn Sensors in Cardiac Assessment: Technologies, Advantages, and Limitations.Sensors (Basel, Switzerland) · 2025Pooled it
- Pooled it
- Impact of Skin Pigmentation on Pulse Oximetry Blood Oxygenation and Wearable Pulse Rate Accuracy: Systematic Review and Meta-Analysis.Journal of medical Internet research · 2024Pooled it
- Publication guidelines for human heart rate and heart rate variability studies in psychophysiology-Part 1: Physiological underpinnings and foundations of measurement.Psychophysiology · 2024Guideline
- Wearable Artificial Intelligence for Detecting Anxiety: Systematic Review and Meta-Analysis.Journal of medical Internet research · 2023Pooled it
- Remote monitoring technologies for measuring cardiovascular functions in community-dwelling adults: a systematic review.GeroScience · 2023Pooled it
- Feasibility and Acceptability of a Smartphone-Delivered Mindfulness Intervention for Stress Reduction in Adult Singaporeans: Pilot Randomized Controlled Trial.JMIR mental health · 2025Trial
- Experimental Analysis on the Effect of Contact Pressure and Activity Level as Influencing Factors in PPG Sensor Performance.Sensors (Basel, Switzerland) · 2025Trial
- Physiological Response to the COVID-19 Vaccine: Insights From a Prospective, Randomized, Single-Blinded, Crossover Trial.Journal of medical Internet research · 2024Trial
- Operationalizing Precision Medicine in Drug Development: Predictive Biomarkers, Companion Diagnostics, and Regulatory Pathways.Clinical pharmacology and therapeutics · 2026Review
- Technology-Enhanced Health Care in Smart Homes: Scoping Review of Sensor Technologies, Clinical Applications, Integration Challenges, and Future Directions.JMIR medical informatics · 2026Article
- Bidirectional Associations Between Autonomic Function, Sleep Quality, and Daily Fatigue and Energy Symptoms in Long COVID: Longitudinal Digital Health Study.JMIR cardio · 2026Observational
- AI Cautionary Guide: Pitfalls and Strategies for the Use of Machine Learning in Medical Research.Clinical pharmacology and therapeutics · 2026Review
- Orthometria: Metric Fixation in Digital Health and a Framework for Responsible Use in High-Performance Sport.Sports medicine - open · 2026Article
- The Representation of Different Populations in Studies Assessing the Validity of Consumer Wearable Photoplethysmography-Based Measurements: Scoping Review.JMIR mHealth and uHealth · 2026Article
- HEART-Watch: A multimodal physiological dataset from a Google Pixel Watch across different physical states.PLOS digital health · 2026Article
- Retrieval-Augmented Large Language Model Counseling for Continuous Glucose Monitoring in Diabetes: Source-Masked Multirater Comparative Evaluation.Journal of medical Internet research · 2026Article
255 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
As wearable technologies are being increasingly used for clinical research and healthcare, it is critical to understand their accuracy and determine how measurement errors may affect research conclusions and impact healthcare decision-making. Accuracy of wearable technologies has been a hotly debated topic in both the research and popular science literature. Currently, wearable technology companies are responsible for assessing and reporting the accuracy of their products, but little information about the evaluation method is made publicly available. Heart rate measurements from wearables are derived from photoplethysmography (PPG), an optical method for measuring changes in blood volume under the skin. Potential inaccuracies in PPG stem from three major areas, includes (1) diverse skin types, (2) motion artifacts, and (3) signal crossover. To date, no study has systematically explored the accuracy of wearables across the full range of skin tones. Here, we explored heart rate and PPG data from consumer- and research-grade wearables under multiple circumstances to test whether and to what extent these inaccuracies exist. We saw no statistically significant difference in accuracy across skin tones, but we saw significant differences between devices, and between activity types, notably, that absolute error during activity was, on average, 30% higher than during rest. Our conclusions indicate that different wearables are all reasonably accurate at resting and prolonged elevated heart rate, but that differences exist between devices in responding to changes in activity. This has implications for researchers, clinicians, and consumers in drawing study conclusions, combining study results, and making health-related decisions using these devices.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.