Basic principles of neonatal bubble CPAP: effects on CPAP delivery and imposed work of breathing when altering the original design.

Sonja Baldursdottir, Markus Falk, Snorri Donaldsson, Baldvin Jonsson, Thomas Drevhammar

Open access · hybridAbstract read
In one paragraph

Article in Archives of disease in childhood. Fetal and neonatal edition, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
2.7field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it, 31 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Review
  11. Review
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Sonja BaldursdottirDepartment of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden.
Markus FalkDepartment of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden.
Snorri DonaldssonDepartment of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden.
Baldvin JonssonDepartment of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden.
Thomas DrevhammarDepartment of Anesthesiology, Östersund Hospital, Östersund, Sweden thomas.drevhammar@ki.se.ORCID http://orcid.org/0000-0002-4038-2221
Karolinska University Hospital · SEKarolinska Institutet · SEÖstersunds Hospital · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe original bubble continuous positive airway pressure (bCPAP) design has wide-bore tubing and a low-resistance interface. This creates a stable airway pressure that is reflected by the submersion depth of the expiratory tubing. Several systems with alterations to the original bCPAP design are now available. Most of these are aimed for use in low-income and middle-income countries and have not been compared with the original design.

objectiveWe identified three major alterations to the original bCPAP design: (1) resistance of nasal interface, (2) volume of dead space and (3) diameter of expiratory tubing. Our aim was to study the effect of these alterations on CPAP delivery and work of breathing in a mechanical lung model. Dead space should always be avoided and was not further tested.

methodsThe effect of nasal interface resistance and expiratory tubing diameter was evaluated with simulated breathing in a mechanical lung model without interface leakage. The main outcome was delivered CPAP and imposed work of breathing.

resultsHigh-resistance interfaces and narrow expiratory tubing increased the work of breathing. Additionally, narrow expiratory tubing resulted in higher CPAP levels than indicated by the submersion depth.

conclusionOur study shows the significant effect on CPAP delivery and imposed work of breathing when using high-resistance interfaces and narrow expiratory tubing in bCPAP systems. New systems should include low-resistance interfaces and wide-bore tubing and be compared with the original bCPAP. Referring to all systems that bubble as bCPAP is misleading and potentially hazardous.

Indexed as

Airway ResistanceContinuous Positive Airway PressureHumansInfant, NewbornModels, BiologicalWork of Breathingintensive careneonatologyrespiratory

Identifiers

PMID32047029
PMCPMC7547905
OpenAlexW3005706048

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.