ArticleKidney international reports2020
Development of a Standardized Chemiluminescence Immunoassay for the Detection of Autoantibodies Against Human M-Type Phospholipase A2 Receptor in Primary Membranous Nephropathy.
Article in Kidney international reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it, 22 citations in OpenAlex.
- PLA2R autoantibodies, a multifaceted biomarker in nephrotic syndrome and membranous nephropathy.Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association · 2025Pooled it
- Time-resolved fluoroimmunoassay improves sensitivity in the diagnosis of primary membranous nephropathy with low phospholipase A2 receptor antibody titer.Scientific reports · 2025Article
- Noninvasive Diagnostic Strategies for Membranous Nephropathy in the Nephrotic Syndrome Study Network.Clinical journal of the American Society of Nephrology : CJASN · 2025Article
- Measurement of urinary exosomal phospholipase A2 receptor is a sensitive method for diagnosis of PLA2R-associated membranous nephropathy.Clinical kidney journal · 2024Article
- Antibody-Guided Therapy in Phospholipase A2 Receptor-Associated Membranous Nephropathy.Kidney international reports · 2023Article
- Serodiagnosis of Anti-glomerular Basement Membrane Disease Using a Newly Developed Chemiluminescence Immunoassay.Frontiers in medicine · 2022Article
- Novel Biomarkers in Membranous Nephropathy.Frontiers in immunology · 2022Review
- Characterization of THSD7A-antibodies not binding to glomerular THSD7A in a patient with diabetes mellitus but no membranous nephropathy.Scientific reports · 2021Article
- Rapid, quantitative, and high-sensitivity detection of anti-phospholipase A2 receptor antibodies using a novel CdSe/ZnS-based fluorescence immunosorbent assay.Scientific reports · 2021Article
- A New Chemiluminescence Immunoassay for Phospholipase AKidney international reports · 2021Article
- Mechanisms of Primary Membranous Nephropathy.Biomolecules · 2021Review
- Designing Clinical Trials for the Treatment of Membranous Nephropathy in the Anti-Phospholipase A2 Receptor 1 Era: Results of a NephCure Membranous Nephropathy Workshop.Glomerular diseasesArticle
- Serum Phospholipase A2 Receptor Antibody Is Associated with Thrombogenesis in Primary Membranous Nephropathy: A Systematic Review and Meta-Analysis.Glomerular diseasesArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 4 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionAutoantibodies against the M-type phospholipase A2 receptor (PLA2R) are important markers in the diagnosis and monitoring of primary membranous nephropathy (pMN). For the detection of anti-PLA2R autoantibodies, a standardized recombinant cell-based indirect immunofluorescence assay (RC-IFA) and enzyme-linked immunosorbent assay (ELISA) are widely used, the former providing higher sensitivity but lacking a finely graduated quantification of antibody titers. In this study, we evaluated the diagnostic performance characteristics of a novel standardized chemiluminescence immunoassay (ChLIA) by comparison with the established anti-PLA2R test systems.
methodsSera from 155 patients with biopsy-proven pMN and 154 disease controls were analyzed for autoantibodies against PLA2R by the novel ChLIA as well as by ELISA and RC-IFA.
resultsThe clinical sensitivity of the ChLIA (83.9%) was higher compared with ELISA (73.5%) and equaled that of RC-IFA (83.2%), at similar specificities (≥99.4%). Among ELISA-negative pMN samples, ChLIA and RC-IFA yielded positive results in 39.0% and 36.6%, respectively. The qualitative agreement amounted to 94.5% (ChLIA vs. ELISA) and 99.4% (ChLIA vs. RC-IFA).
conclusionThe novel anti-PLA2R ChLIA outperforms the ELISA in detecting patients with pMN and demonstrates almost perfect agreement with RC-IFA. It thus presents a promising alternative tool for accurate anti-PLA2R testing, with the advantage of rapid turnaround times and fully automated random-access processing.
Indexed as
Identifiers
What OpenQuestion holds